Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/01/2006 | PLUMBING - FINAL | Approved | IVRS - Inspection :* | |
| 12/01/2006 | PLUMBING - FINAL | Partial Approval | IVRS - Inspection :* TEST IS OK SUPPORT VERTICAL PIPE AT WH AND FURNACE PROTECT BELOW GROUND PIPING W/PRIMER AND 10 MIL TAPE OK FOR GAS AFTER CORRECTING OK TO FINAL AFTER APPROVING FAV |
|
| 11/29/2006 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1. HAVE NEW FAV INSPECTED AND PROVIDE PROOF OF INSPECTION. 2. COMPLETE VENTING OF FAV AND WH 3. TEST ALL GAS PIPING INCLUDING TEES WITH A 15 PSI 4. GAUGE WITH 1/10 PSI INCREMENTATIONS. 5. SECURE PIPING IN ATTIC NOTE: THE USE OF CSST IS ACCEPTABLE WHEN SHOWN ON PLAN. T&P APPEARS TO HAVE BEEN INSTALLED UNDER PRIOR CODES AND CAN REMAIN UNTIL WH IS REPLACED. |