Permit: T06PL01938
Permit Details
Apply Date:
10/27/2006
Applicant:
ETCHART'S LAKESIDE PLUMBING INC
Description:
GAS LINE:REPIPE
Contractors:
- ETCHART'S LAKESIDE PLUMBING INC
Permit Reviews
Permit Number - T06PL01938
Permit Status: Final
Permit Description: GAS LINE:REPIPE
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 10/27/2006 | PLUMBING | 10/27/2006 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T06PL01938
Permit Status: Final
Permit Description: GAS LINE:REPIPE
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 10/27/2006 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T06PL01938
Permit Description: GAS LINE:REPIPE
Total Completed Inspections - 3
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/02/2006 | PLUMBING - GAS PRESSURE TEST | RLEDONNE | Approved | IVRS - Inspection :* 1. PROVIDE 1" CLEARANCE ROUND FLUE VENT THRU ROOF 2. REMOVE PAINT THINNER AND PAINT FROM ROOM #1 FURN 3. FURN #2 REMOVE TAPE FROM FLUE VENT 4. FURN #2 PROVIDE SCREWS AT JOINTS FOR FLUE VENT 5. PROVIDE 1" CLEAR ROUND FLUE VENT THRU ROOF. 6. IF FLUE VENT IS WITHIN 10' OF AIR INTAKE (COOLER) NEEDS TO BE 3' ABOVE AN INTAKE (COOLER) ON ALL FURNACES. 7. PROVIDE 1" CLEAR ROUND FLUE VENT THROUGH ROOF ON #3, #42, #5 FURNACES. 8. PROVIDE VENTS FROM REGULATORS TO OUTSIDE OF BUILDING. 9. RUN T&P OFF WATER HEATER TO DAYLIGHT 10. PROVIDE APPROVAL FOR FLUE VENT OF WATER HEATER 11. PROVIDE VALVE ON COLD WATER SUPPLY TO WATER HEATER 12. CALL BACK FOR FINAL 13. PRESSURE TEST OK 14. OK TO COVER UNDERGROUND. |
| 12/01/2006 | PERMIT FINALED | BFLORES | Approved | |
| 12/01/2006 | PLUMBING - FINAL | BBENEDON | Approved |