Permit: T06PL01938

Parcel: 127060170


Addresses:

4741 E BROADWAY BL


Inspection Status: Approved

Inspection History: PLUMBING - GAS PRESSURE TEST

Permit Number - T06PL01938

Inspection Description - PLUMBING - GAS PRESSURE TEST

Inspection Status - Approved

Date Description Inspector Results Comments
11/02/2006 PLUMBING - GAS PRESSURE TEST Approved IVRS - Inspection :*
1. PROVIDE 1" CLEARANCE ROUND FLUE VENT THRU ROOF
2. REMOVE PAINT THINNER AND PAINT FROM ROOM #1 FURN
3. FURN #2 REMOVE TAPE FROM FLUE VENT
4. FURN #2 PROVIDE SCREWS AT JOINTS FOR FLUE VENT
5. PROVIDE 1" CLEAR ROUND FLUE VENT THRU ROOF.
6. IF FLUE VENT IS WITHIN 10' OF AIR INTAKE (COOLER) NEEDS TO BE 3' ABOVE AN INTAKE (COOLER) ON ALL FURNACES.
7. PROVIDE 1" CLEAR ROUND FLUE VENT THROUGH ROOF ON #3, #42, #5 FURNACES.
8. PROVIDE VENTS FROM REGULATORS TO OUTSIDE OF BUILDING.
9. RUN T&P OFF WATER HEATER TO DAYLIGHT
10. PROVIDE APPROVAL FOR FLUE VENT OF WATER HEATER
11. PROVIDE VALVE ON COLD WATER SUPPLY TO WATER HEATER
12. CALL BACK FOR FINAL
13. PRESSURE TEST OK
14. OK TO COVER UNDERGROUND.