Permit: T06PL01609
Permit Details
Status:
Expired
Type:
MULTI FAMILY OTHER
Address:
6614 E CALLE DE SAN ALBERTO
Address NEW:
6614 E CALLE DE SAN ALBERTO
Apply Date:
09/06/2006
Applicant:
DENSON JERRY
Description:
Gas line repipe
Contractors:
- DRAINMASTERS L L C *C
Outstanding Activity Conditions
Permit Number - T06PL01609
Permit Status: Expired
Permit Description: Gas line repipe
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 09/06/2006 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Expired
Permit Number: T06PL01609
Permite Description: Gas line repipe
Total Outstanding Inspections - 1
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/08/2006 | PLUMBING - FINAL | N/A | Denied | IVRS - Inspection : See detailed listing on site.| 999* 300 NORTH GAS DEMAND IS 300,000 BTU TOTAL LENGTH APPROX. 60' 1 1/4" PIPING IS REQUIRED TO FIRST FURNACE. 1" REQUIRED TO SUPPLY SECOND FURNACE AND WH TEE SHALL BE FULL SIZE PROVIDE PLAN FOR GAS PIPING AND INSTALLATION OF NEW FURNACE. INSTALLATION OF NEW FURNACE REQUIRES MECHANICAL PERMIT. HAVE MECHANICAL INSPECTION PRIOR TO GAS INSPECTION. PETITION OF APPEAL REQUIRED IF T&P CANNOT TERMINATE OUTSIDE. SEDIMENT TRAPS REQUIRED. NO TAPE AT VENT CONNECTOR TO VENT CONNECTION SUPPORT PIPING AT WH SEAL WALL PENETRATION. |