Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Expired
Type:
MULTI FAMILY OTHER
Apply Date:
09/06/2006
Applicant:
DENSON JERRY
Description:
Gas line repipe
Contractors:
  • DRAINMASTERS L L C *C

Outstanding Activity Conditions

Permit Number - T06PL01609
Permit Status: Expired
Permit Description: Gas line repipe
Total Outstanding Activity Conditions - 1
Date Name
09/06/2006 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Outstanding Inspections

Permit Status: Expired
Permit Number: T06PL01609
Permite Description: Gas line repipe
Total Outstanding Inspections - 1
Last Inspection Date Description Inspector Results Comments
09/08/2006 PLUMBING - FINAL N/A Denied IVRS - Inspection :
See detailed listing on site.| 999*
300 NORTH
GAS DEMAND IS 300,000 BTU
TOTAL LENGTH APPROX. 60'
1 1/4" PIPING IS REQUIRED TO FIRST FURNACE.
1" REQUIRED TO SUPPLY SECOND FURNACE AND WH
TEE SHALL BE FULL SIZE
PROVIDE PLAN FOR GAS PIPING AND INSTALLATION OF NEW FURNACE.
INSTALLATION OF NEW FURNACE REQUIRES MECHANICAL PERMIT.
HAVE MECHANICAL INSPECTION PRIOR TO GAS INSPECTION.
PETITION OF APPEAL REQUIRED IF T&P CANNOT TERMINATE OUTSIDE.
SEDIMENT TRAPS REQUIRED.
NO TAPE AT VENT CONNECTOR TO VENT CONNECTION
SUPPORT PIPING AT WH
SEAL WALL PENETRATION.

Documents

File Name Document Type  
T06PL01609.PDF DOCUMENTS VIEW