Permit: T06PL01487
Permit Details
Apply Date:
08/16/2006
Applicant:
DON BROWN
Description:
RELOCATE GAS METER
Permit Reviews
Permit Number - T06PL01487
Permit Status: Expired
Permit Description: RELOCATE GAS METER
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 08/16/2006 | PLUMBING | 08/16/2006 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T06PL01487
Permit Status: Expired
Permit Description: RELOCATE GAS METER
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 08/16/2006 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Expired
Permit Number: T06PL01487
Permite Description: RELOCATE GAS METER
Total Outstanding Inspections - 2
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/25/2006 | PLUMBING - GAS PRESSURE TEST | N/A | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
| 08/25/2006 | PLUMBING - FINAL | N/A | Denied | IVRS - Inspection : See detailed listing on site.| 999* - YOUR PERMIT IS FOR RELOCATING GAS METER. - RELOCATING AND REPLACING A GAS WATER HEATER REQUIRES A PERMIT. YOU CAN HAVE THIS ADDED TO THIS PERMIT. - 3/4 PIPING SUPPLING 117,000 BTU WH AND 80,000 BTU FURNACE AT 60' IS UNDERSIZED. - PROVIDE 1" PIPING TO BRANCH CONNECTION FOR WH. - HAVE MECHANICAL INSPECTION APPROVED BEFORE RECALLING |