Permit Details

Status:
Expired
Type:
SINGLE FAMILY OTHER
Address NEW:
7942 E ROSEWOOD ST
Apply Date:
06/01/2006
Applicant:
WILKENSON MIKE
Description:
REPLACE:GAS LINE
Contractors:
  • SATHER PLUMBING CONTRACTOR , T O

Outstanding Activity Conditions

Permit Number - T06PL00901
Permit Status: Expired
Permit Description: REPLACE:GAS LINE
Total Outstanding Activity Conditions - 1
Date Name
06/01/2006 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Outstanding Inspections

Permit Status: Expired
Permit Number: T06PL00901
Permite Description: REPLACE:GAS LINE
Total Outstanding Inspections - 1
Last Inspection Date Description Inspector Results Comments
06/01/2006 PLUMBING - FINAL N/A Denied IVRS - Inspection :
See detailed listing on site.| 999*
MIKE 906-2611
REQUESTED AFTER HOURS INSPECTION
PAID WITH CHECK NO. 8542
GAS PRESSURE TEST IS OK
YARD PIPING IS OK TO COVER
1. WATER HEATER T&P RELIEF DRAIN CANNOT GO UP THRU ROOF.
IF YOU ARE UNABLE TO RUN A GRAVITY DRAIN LINE TO EXTERIOR YOU MAY APPLY FOR A PETITION OF APPEAL AT THE PERMIT COUNTER AT 201 N. STONE
THE PET. OF APPEAL WILL REQUIRE A 125 PSI RELIEF DRAIN TO BE INSTALLED OUTSIDE AND WH TO HAVE A DRAIN PAN INSTALLED UNDER WH.
2. B-VENT TERMINATION WITHIN 10' OF COOLER SHALL BE EXTENDED TO TWO FEET ABOVE TOP OF COOLER.
3. SECURE VENT CONNECTOR W/GALV SHEET METAL SCREWS,
4. PROVIDE ELECTRICAL BONDING OF GAS LINE.

Completed Inspections

Permit Status: Expired
Permit Number: T06PL00901
Permit Description: REPLACE:GAS LINE
Total Completed Inspections - 1
Date Description Inspector Results Comments
06/01/2006 PLUMBING - GAS PRESSURE TEST BBENEDON Approved IVRS - Inspection :*