Permit: T06PL00901

Parcel: 133270060


Addresses:

7942 E ROSEWOOD ST

Inspection Status: Denied

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
06/01/2006 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
MIKE 906-2611
REQUESTED AFTER HOURS INSPECTION
PAID WITH CHECK NO. 8542
GAS PRESSURE TEST IS OK
YARD PIPING IS OK TO COVER
1. WATER HEATER T&P RELIEF DRAIN CANNOT GO UP THRU ROOF.
IF YOU ARE UNABLE TO RUN A GRAVITY DRAIN LINE TO EXTERIOR YOU MAY APPLY FOR A PETITION OF APPEAL AT THE PERMIT COUNTER AT 201 N. STONE
THE PET. OF APPEAL WILL REQUIRE A 125 PSI RELIEF DRAIN TO BE INSTALLED OUTSIDE AND WH TO HAVE A DRAIN PAN INSTALLED UNDER WH.
2. B-VENT TERMINATION WITHIN 10' OF COOLER SHALL BE EXTENDED TO TWO FEET ABOVE TOP OF COOLER.
3. SECURE VENT CONNECTOR W/GALV SHEET METAL SCREWS,
4. PROVIDE ELECTRICAL BONDING OF GAS LINE.