Inspection History Details
Inspection Status: Denied
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/01/2006 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* MIKE 906-2611 REQUESTED AFTER HOURS INSPECTION PAID WITH CHECK NO. 8542 GAS PRESSURE TEST IS OK YARD PIPING IS OK TO COVER 1. WATER HEATER T&P RELIEF DRAIN CANNOT GO UP THRU ROOF. IF YOU ARE UNABLE TO RUN A GRAVITY DRAIN LINE TO EXTERIOR YOU MAY APPLY FOR A PETITION OF APPEAL AT THE PERMIT COUNTER AT 201 N. STONE THE PET. OF APPEAL WILL REQUIRE A 125 PSI RELIEF DRAIN TO BE INSTALLED OUTSIDE AND WH TO HAVE A DRAIN PAN INSTALLED UNDER WH. 2. B-VENT TERMINATION WITHIN 10' OF COOLER SHALL BE EXTENDED TO TWO FEET ABOVE TOP OF COOLER. 3. SECURE VENT CONNECTOR W/GALV SHEET METAL SCREWS, 4. PROVIDE ELECTRICAL BONDING OF GAS LINE. |