Permit Details

Status:
Expired
Type:
SINGLE FAMILY OTHER
Address NEW:
4767 S APPLE TREE AV
Apply Date:
05/16/2006
Applicant:
KEPPLER CARL JR & DOROTHY M
Description:
REPL: GAS LINE

Permit Reviews

Permit Number - T06PL00816
Permit Status: Expired
Permit Description: REPL: GAS LINE
Start Date Submittal Complete Date Status  
05/16/2006 PLUMBING 05/16/2006 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T06PL00816
Permit Status: Expired
Permit Description: REPL: GAS LINE
Total Outstanding Activity Conditions - 1
Date Name
05/16/2006 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Outstanding Inspections

Permit Status: Expired
Permit Number: T06PL00816
Permite Description: REPL: GAS LINE
Total Outstanding Inspections - 2
Last Inspection Date Description Inspector Results Comments
05/18/2006 PLUMBING - GAS PRESSURE TEST N/A Denied IVRS - Inspection :
See detailed listing on site.| 999*
05/18/2006 PLUMBING - FINAL N/A Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. PROVIDE PRESSURE TEST ON GAS SYSTEM IN ITS ENTIRETY
2. PROVIDE AGA OR CSA APPROVED GAS VALVES AT ALL APPLIANCES.
3. GAS SHUT OFF VALVE FOR FIREPLACE SHALL BE OUTSIDE OF FIREPLACE HEARTH WITHIN 4' OF HEARTH AND BE TESTED INTO FIREPLACE HEARTH.
4. WATER HEATER TEMPERATURE & PRESSURE RELIEF DRAIN PIPING SHALL GRAVITY TO DAYLIGHT OR PROVIDE CITY SIGNED PETITION OF APPEAL ON SITE WITH CORRECT INSTALLATION.
4.5 WATER HEATER VENT SHALL BE MADE UP CORRECTLY.
5. ALL GAS PIPING SHALL BE SUPPORTED AND SECURED CORRECTLY.
6. NO GAS PIPING SHALL BE RAN UNDERGROUND UNDER THE BUILDING OR STRUCTURE.
7. VENTS FROM WATER HEATER & FURNACE SHALL BE EXTENDED 3' FOR WATER HEATER, 2' FOR FURNACE ABOVE TOP OF AIR INTAKE FOR COOLER WHEN WITHIN 10' OF INTAKE WITH DOUBLE WALL VENT PIPING AND CAP. PROVIDE 3-GALV SCREWS AT ALL VENT JOINTS.
HOMEOWNERS MAY DO WORK THEMSELVES IF LIVING IN STRUCTURE. OTHERWISE A LICENSED CONTRACTOR IS REQUIRED.