Permit: T06PL00816

Parcel: 136282140

Inspection Status: Denied

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
05/18/2006 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. PROVIDE PRESSURE TEST ON GAS SYSTEM IN ITS ENTIRETY
2. PROVIDE AGA OR CSA APPROVED GAS VALVES AT ALL APPLIANCES.
3. GAS SHUT OFF VALVE FOR FIREPLACE SHALL BE OUTSIDE OF FIREPLACE HEARTH WITHIN 4' OF HEARTH AND BE TESTED INTO FIREPLACE HEARTH.
4. WATER HEATER TEMPERATURE & PRESSURE RELIEF DRAIN PIPING SHALL GRAVITY TO DAYLIGHT OR PROVIDE CITY SIGNED PETITION OF APPEAL ON SITE WITH CORRECT INSTALLATION.
4.5 WATER HEATER VENT SHALL BE MADE UP CORRECTLY.
5. ALL GAS PIPING SHALL BE SUPPORTED AND SECURED CORRECTLY.
6. NO GAS PIPING SHALL BE RAN UNDERGROUND UNDER THE BUILDING OR STRUCTURE.
7. VENTS FROM WATER HEATER & FURNACE SHALL BE EXTENDED 3' FOR WATER HEATER, 2' FOR FURNACE ABOVE TOP OF AIR INTAKE FOR COOLER WHEN WITHIN 10' OF INTAKE WITH DOUBLE WALL VENT PIPING AND CAP. PROVIDE 3-GALV SCREWS AT ALL VENT JOINTS.
HOMEOWNERS MAY DO WORK THEMSELVES IF LIVING IN STRUCTURE. OTHERWISE A LICENSED CONTRACTOR IS REQUIRED.