Permit: T06PL00705
Permit Details
Apply Date:
05/02/2006
Applicant:
ARIZONA PLUMBING SERVICES *C
Description:
REPLC: 30 GAL GAS WTR HEATER (APA)
Contractors:
- ARIZONA PLUMBING SERVICES *C
Outstanding Activity Conditions
Permit Number - T06PL00705
Permit Status: Expired
Permit Description: REPLC: 30 GAL GAS WTR HEATER (APA)
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 05/02/2006 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Expired
Permit Number: T06PL00705
Permite Description: REPLC: 30 GAL GAS WTR HEATER (APA)
Total Outstanding Inspections - 1
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/13/2006 | PLUMBING - FINAL | N/A | Denied | IVRS - Inspection : See detailed listing on site.| 999* - WATER HEATER PLATFORM IS COLLAPSING. - WH IS LEANING. - T&P TERMINATION IS IN GARAGE. - T&P CONNECTED W/FLEX. FLEX HAS KINK. - CORRECT PLATFORM - PROVIDE DRAIN PAN, MAY DRAIN INTO GARAGE. - TERMINATE T&P OUTSIDE WITH APPROVED MATERIALS, - FLEX IS NOT ALLOWED - REMOVE TAPE FROM SINGLE WALL TO DOUBLE WALL VENT TRANSITION - SECURE VENT W/SCREWS - SEDIMENT TRAP REQUIRED. |