Permit Details

Status:
Expired
Type:
SINGLE FAMILY OTHER
Address NEW:
7321 E LAKESIDE DR
Apply Date:
03/07/2006
Applicant:
ARIZONA PLUMBING SERVICES, DBA SEARS,*C
Description:
REPL: WATER HEATER (APA)
Contractors:
  • ARIZONA PLUMBING SERVICES, DBA SEARS,*C

Outstanding Activity Conditions

Permit Number - T06PL00408
Permit Status: Expired
Permit Description: REPL: WATER HEATER (APA)
Total Outstanding Activity Conditions - 1
Date Name
03/07/2006 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Outstanding Inspections

Permit Status: Expired
Permit Number: T06PL00408
Permite Description: REPL: WATER HEATER (APA)
Total Outstanding Inspections - 1
Last Inspection Date Description Inspector Results Comments
04/27/2006 PLUMBING - FINAL N/A Denied IVRS - Inspection :
See detailed listing on site.| 999*
WATER HEATER IS ON WITH NO FLUE VENT CONNECTION THRU ROOF.
ADVISED OWNER TO TURN OFF GAS SUPPLY TO HEATER.
SHE DID BECAUSE OF DANGEROUS SITUATION.
ALSO ADVISED OWNER OF HAZARDS OF CARBON MONOXIDE.
1. VENT TO BE CORRECTLY CONNECTED, ALL VENT JOINTS TO BE PROVIDED WITH 3-GALV SCREWS.
2. WATER HEATER TEMPERATURE & PRESSURE RELIEF DRAIN TO BE GRAVITY DRAIN TO DAYLIGHT OR PROVIDE CITY SIGNED PETITION OF APPEAL ON SITE WITH CORRECT INSTALLATION.