Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T06PL00408

Parcel: 136343950


Addresses:

7321 E LAKESIDE DR

Inspection Status: Denied

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
04/27/2006 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
WATER HEATER IS ON WITH NO FLUE VENT CONNECTION THRU ROOF.
ADVISED OWNER TO TURN OFF GAS SUPPLY TO HEATER.
SHE DID BECAUSE OF DANGEROUS SITUATION.
ALSO ADVISED OWNER OF HAZARDS OF CARBON MONOXIDE.
1. VENT TO BE CORRECTLY CONNECTED, ALL VENT JOINTS TO BE PROVIDED WITH 3-GALV SCREWS.
2. WATER HEATER TEMPERATURE & PRESSURE RELIEF DRAIN TO BE GRAVITY DRAIN TO DAYLIGHT OR PROVIDE CITY SIGNED PETITION OF APPEAL ON SITE WITH CORRECT INSTALLATION.