Description:
REPLACE GASLINE
Permit Reviews
Permit Number - T06PL00278
Permit Status: Expired
Permit Description: REPLACE GASLINE
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 02/13/2006 | PLUMBING | 02/13/2006 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T06PL00278
Permit Status: Expired
Permit Description: REPLACE GASLINE
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 02/13/2006 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Expired
Permit Number: T06PL00278
Permite Description: REPLACE GASLINE
Total Outstanding Inspections - 1
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/16/2006 | PLUMBING - FINAL | N/A | Not ready for Inspection | IVRS - Inspection :* |
Completed Inspections
Permit Status: Expired
Permit Number: T06PL00278
Permit Description: REPLACE GASLINE
Total Completed Inspections - 1
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/16/2006 | PLUMBING - GAS PRESSURE TEST | RRICH | Approved | IVRS - Inspection :* 03050 -- 20 PSI TEST FROM METER ABOVE GROUND TO EXISTING SERVICE ENTRANCE TO ROOFTOP UNIT & WATER HEATER OK 1. PROVIDE CORRECT SUPPORT ON ALL GAS PIPING. 2. PROVIDE DRAIN PIPE FOR WATER HEATER TEMPERATURE & PRESSURE RELIEF 3. MAKE UP VENT FROM WATER HEATER & PROVIDE 3-GALV SCREWS AT EACH JOINT. 4. PROVIDE PRIMER & TEN MIL. TAPE ON PIPING AT RISER AT METER. GAS CARD AT METER 889-1888 |