Permit Details

Status:
Expired
Type:
MULTI FAMILY OTHER
Address NEW:
109 W PRINCE RD #05
Apply Date:
01/18/2006
Applicant:
SISSON PLUMBING
Description:
REPAIR:GAS
Contractors:
  • SISSON PLUMBING

Outstanding Activity Conditions

Permit Number - T06PL00097
Permit Status: Expired
Permit Description: REPAIR:GAS
Total Outstanding Activity Conditions - 1
Date Name
01/18/2006 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Outstanding Inspections

Permit Status: Expired
Permit Number: T06PL00097
Permite Description: REPAIR:GAS
Total Outstanding Inspections - 2
Last Inspection Date Description Inspector Results Comments
01/19/2006 PLUMBING - GAS PRESSURE TEST N/A Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. GAS SYSTEM HAS 235,000 BTU DEMAND TOTAL PIPING IS UNDERSIZED. SUPPLY CITY APPROVED GAS ISOMETRIC PLAN IWHT INSTALLATION OF GAS PIPING.
2. WATER HEATER AT UNIT D HAS BEEN CHANGED TO ELECTRIC WITHOUT PERMITS.
01/19/2006 PLUMBING - FINAL N/A Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. PROVIDE ROOF FLASHING AT ROOF FOR VENT, UNIT C PROVIDE DOUBLE WALL VENT PIPING FROM ENCLOSURE THRU ROOF WITH APPROVED VENT CAP WITH 3-GALV SCREWS AT EACH JOINT OF VENT PIPING.
2. PROVIDE MINIMUM 100 SQ INCHES UPPER & LOWER COMBUSTION AIR OPENING FOR WATER HEATER.
3. PROVIDE NEW FITTINGS FOR PIPING.
4. SEAL PENETRATIONS INTO BUILDING AROUND GAS PIPING
5. SECURE GAS PIPING IN ATTIC OF UNIT C
6. PROVIDE WATER HEATER PULL SPACE FOR WATER HEATER IN UNIT D

Documents

File Name Document Type  
None DOCUMENTS VIEW