Inspection History Details
Inspection Status: Denied
Inspection History: PLUMBING - FINAL
Permit Number - T06PL00097
Inspection Description - PLUMBING - FINAL
Inspection Status - Denied
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/19/2006 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. PROVIDE ROOF FLASHING AT ROOF FOR VENT, UNIT C PROVIDE DOUBLE WALL VENT PIPING FROM ENCLOSURE THRU ROOF WITH APPROVED VENT CAP WITH 3-GALV SCREWS AT EACH JOINT OF VENT PIPING. 2. PROVIDE MINIMUM 100 SQ INCHES UPPER & LOWER COMBUSTION AIR OPENING FOR WATER HEATER. 3. PROVIDE NEW FITTINGS FOR PIPING. 4. SEAL PENETRATIONS INTO BUILDING AROUND GAS PIPING 5. SECURE GAS PIPING IN ATTIC OF UNIT C 6. PROVIDE WATER HEATER PULL SPACE FOR WATER HEATER IN UNIT D |