Permit: T06OT03184
Permit Details
Apply Date:
12/08/2006
Applicant:
SPENCER SIGNS *C
Description:
12323
Contractors:
- SPENCER SIGNS *C
Completed Inspections
Permit Status: Final
Permit Number: T06OT03184
Permit Description: 12323
Total Completed Inspections - 5
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
12/15/2006 | SIGN SITE REVIEW | JYBARRA | Approved | |
12/21/2006 | SIGN SHOP | RHOLLAND | Approved | IVRS - Inspection : The wiring is not complete or does not comply with code.| 245* 1. MAINTAIN GTO CLEARANCE 1 1/2" FROM GROUNDED SURFACES SPAGHETTI GLASS NON-EFFECTIVE 2. USE CORRECT SIZED BOOT FOR GTO CABLE DO NOT CUT SLEEVING. 3. CANNOT USE 600 V TERMINAL END ON 15,000V CABLE 4. ONLY ONE CONDUCTOR TO A TERMINAL CONNECTION. |
02/05/2007 | SIGN INSPECTION | JYBARRA | Approved | IVRS - Inspection :* |
02/07/2007 | SIGN ELECTRIC | RHOLLAND | Approved | IVRS - Inspection :* |
02/08/2007 | PERMIT FINALED | JWEATHER | Approved |