Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
Final
Type:
SIGN PERMIT
Apply Date:
10/20/2006
Applicant:
SIGN SERVICES
Description:
12029
Contractors:
  • SIGN SERVICES

Completed Inspections

Permit Status: Final
Permit Number: T06OT02729
Permit Description: 12029
Total Completed Inspections - 5
Date Description Inspector Results Comments
10/27/2006 SIGN SITE REVIEW JSONKIN Approved IVRS - Inspection :*
12/15/2006 SIGN ELECTRIC RHOLLAND Approved IVRS - Inspection :
See detailed listing on site.| 999*
1. MISSING JUNCTION BOX COVER
2. FILL UNUSED OPENING IN ENCLOSURES & LETTERS
3. TIGHTEN LOOSE FITTINGS ENCLOSURES & LETTERS
4. PROVIDE A SERVICE LIGHTS 210.7(C)
5. MAINTAIN GTO CLEARANCES - 1 1/2"
6. DO NOT ENERGIZE SIGN UNTIL FINALED BY ELECTRICAL INSPECTOR.
7. A MARKING LABEL IS NEEDED 600.4
8. NEED CITY STICKERS ON SITE
9. WALKWAY TO HAVE 12" MINIMUM ENTIRE LENGTH.
12/15/2006 SIGN SHOP RHOLLAND Approved IVRS - Inspection :
See detailed listing on site.| 999*
01/18/2007 SIGN INSPECTION JYBARRA Approved IVRS - Inspection :*
01/19/2007 PERMIT FINALED LJACKSON Approved

Documents

File Name Document Type  
PERMITPACKET.PDF SIGNS VIEW