Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
N/A
Type:
N/A
Address:
2301 E SYLVIA ST
Address NEW:
2301 E SYLVIA ST
Apply Date:
N/A
Applicant:
GOEBEL GARTH & SHELLIE JT/RS
Description:
N/A

Permit Reviews

Permit Number - T06OT02507
Permit Status:
Permit Description:
Start Date Submittal Complete Date Status  
09/27/2006 FLOODPLAIN 01/03/2007 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T06OT02507
Permit Status:
Permit Description:
Total Outstanding Activity Conditions - 1
Date Name
10/13/2006 October 13, 2006 FLOODPLAIN USE PERMIT NO.: T06OT02507 RELATED PERMIT NO.: T06CM05165 ADDRESS: 2301 E. Sylvia St. APPLICANT: Garth Goebel The applicant is authorized to use a portion of the City of Tucson property described as (legal description): COPPER TERRACE LOT 24 1. This permit is for the purpose of construction of an addition to an existing single-family residence within a mapped Special Flood Hazard Area (SFHA), Zone AE, as shown on the Flood Insurance Rate Map (FIRM), Community Panel No. 040076-04019C-1639K, effective date February 8, 1999. 2. The proposed development is impacted by the regulatory floodplain. For purposes of this permit, the following elevation requirements apply: Base Flood Elevation (BFE) = 2406.0 feet per the National Geodetic Vertical Datum (NGVD '29) Regulatory Flood Elevation (RFE) = 2407.0 feet per the National Geodetic Vertical Datum (NGVD '29) The top of the lowest finished floor (FFE) of the addition shall be elevated at or above the Regulatory Flood Elevation (RFE). Service facilities, such as electrical equipment, shall be constructed at or above the RFE and either be placed on flood proof materials or be adequately flood proofed. Prior to the pouring of the first slab or finish floor installation, a Building-Under-Construction Elevation Certificate, completed and certified by an Arizona Registered Land Surveyor, must be returned to the Engineering Division of the Development Services Department. A hold will be placed on the slab inspection (P2S) until the Elevation Certificate has been returned and approved. Prior to any final inspections, a Finished Construction Elevation Certificate, completed and certified by an Arizona Registered Land Surveyor, must be returned to the Engineering Division. A hold will be placed on the final inspection (P2F) until the Elevation Certificate has been returned and approved. 3. One three-foot opening is permitted between the existing non-conforming pre-FIRM residence and the proposed addition. If more openings or a larger opening is added, the existing residence must be brought into compliance with the floodplain Ordinance (i.e., lowest finished floor must be elevated to the RFE). 4. Any additional improvements, including pools, block walls and fences, will require a separate Floodplain Use Permit prior to construction.

Documents

File Name Document Type  
None DOCUMENTS VIEW
FINISHED T06OT02507 20SEPT07.TIF ELEVATION CERT VIEW
EXISTING 7SEPT06.PDF ELEVATION CERT VIEW
INTERMEDIATE T06OT02507 8MAR2007.PDF ELEVATION CERT VIEW