Permit: T06OT01488
Permit Details
Apply Date:
06/05/2006
Applicant:
CINDY BORIS
Description:
C OF O: RESTAURANT
Permit Reviews
Permit Number - T06OT01488
Permit Status: Closed
Permit Description: C OF O: RESTAURANT
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
06/05/2006 | C OF O | 06/15/2006 | COMPLETED |
Outstanding Inspections
Permit Status: Closed
Permit Number: T06OT01488
Permite Description: C OF O: RESTAURANT
Total Outstanding Inspections - 4
Last Inspection Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/22/2006 | BUILDING - FINAL | N/A | Not ready for Inspection | IVRS - Inspection :* |
06/22/2006 | ELECTRIC - FINAL | N/A | Partial Approval | IVRS - Inspection :* C OF O (ELEC) SUBJECT TO REPAIR NOTE: PLEASE CONTACT LANDLORD AND HAVE THEM REPAIR THE CUT-STOLEN GROUNDING ELECTRODE CONDUCTOR AT 4558 E. BROADWAY AS WELL AS THE REST OF THE COMPLEX. *SECURE J-BOX AS DISCUSSED *SECURE CONDUIT NEXT TO PIZZA OVEN AS DISCUSSED |
06/23/2006 | PLUMBING - FINAL | N/A | Not ready for Inspection | 1. WASH & RINSE CAN BE COMBINED BUT SANITIZE BOWL AT 3-COMP SINK TO BE SEPARATE FROM WASH & RINSE. 2. PROVIDE VACUUM BREAKER AT HOSE BIB UNDER 3-COMP SINK. 3. SPRAY HOSE AT 3-COMP SINK TO HAVE CORRECT BACKFLOW PROTECTION OR BE SPRING TYPE DEVICE TO NOT LET THERE BE A POSSIBILITY OF SUBMERGED INLET. 4. DRAINS FROM ICE MACHINE TO BE SEPERATE FOR BIN STORAGE & CONDENSATE. 5. ICE MACHINE TO HAVE BACKFLOW PROTECTION FOR WATER INLET OR PROOF OF 1" AIR GAP. 6. SODA DISPENSER WATER SUPPLY SHALL HAVE REDUCED PRESSURE PRINCIPAL BACKFLOW DEVICE FOR CARBONATOR, AND DOUBLE CHECK BACKFLOW PREVENTOR FOR NON-CARBONATED WATER SUPPLY. 7. ALL BACKFLOW DEVICES IN HOUSE TO BE CERTIFIED. 8. ALL INDIRECT DRAINS TO HAVE 1" MINIMUM AIR GAP. |
06/23/2006 | MECHANICAL - FINAL | N/A | Partial Approval | IVRS - Inspection :* AS PER DISCUSSION W/MANAGER PROVIDE CLEARANCE AROUND PIZZA OVEN 13.1 VENT PIPE THRU WALL. |
Completed Inspections
Permit Status: Closed
Permit Number: T06OT01488
Permit Description: C OF O: RESTAURANT
Total Completed Inspections - 3
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/16/2006 | FIRE - FINAL | FCONTRER | Approved | PER INSP COPY |
06/16/2006 | CERTIFICATE OF OCCUPANCY | JBURGE | Approved | IVRS - Inspection :* |
06/23/2006 | SIGN - FINAL | JYBARRA | Approved | IVRS - Inspection :* |