Permit Reviews

Permit Number - T06OT01488
Permit Status: Closed
Permit Description: C OF O: RESTAURANT
Start Date Submittal Complete Date Status  
06/05/2006 C OF O 06/15/2006 COMPLETED Review Details

Outstanding Inspections

Permit Status: Closed
Permit Number: T06OT01488
Permite Description: C OF O: RESTAURANT
Total Outstanding Inspections - 4
Last Inspection Date Description Inspector Results Comments
06/22/2006 BUILDING - FINAL N/A Not ready for Inspection IVRS - Inspection :*
06/22/2006 ELECTRIC - FINAL N/A Partial Approval IVRS - Inspection :*
C OF O (ELEC) SUBJECT TO REPAIR
NOTE: PLEASE CONTACT LANDLORD AND HAVE THEM REPAIR THE CUT-STOLEN GROUNDING ELECTRODE CONDUCTOR AT 4558 E. BROADWAY AS WELL AS THE REST OF THE COMPLEX.
*SECURE J-BOX AS DISCUSSED
*SECURE CONDUIT NEXT TO PIZZA OVEN AS DISCUSSED
06/23/2006 PLUMBING - FINAL N/A Not ready for Inspection 1. WASH & RINSE CAN BE COMBINED BUT SANITIZE BOWL AT 3-COMP SINK TO BE SEPARATE FROM WASH & RINSE.
2. PROVIDE VACUUM BREAKER AT HOSE BIB UNDER
3-COMP SINK.
3. SPRAY HOSE AT 3-COMP SINK TO HAVE CORRECT BACKFLOW
PROTECTION OR BE SPRING TYPE DEVICE TO NOT LET
THERE BE A POSSIBILITY OF SUBMERGED INLET.
4. DRAINS FROM ICE MACHINE TO BE SEPERATE FOR BIN STORAGE & CONDENSATE.
5. ICE MACHINE TO HAVE BACKFLOW PROTECTION FOR WATER INLET OR PROOF OF 1" AIR GAP.
6. SODA DISPENSER WATER SUPPLY SHALL HAVE REDUCED PRESSURE PRINCIPAL BACKFLOW DEVICE FOR CARBONATOR, AND DOUBLE CHECK BACKFLOW PREVENTOR FOR NON-CARBONATED WATER SUPPLY.
7. ALL BACKFLOW DEVICES IN HOUSE TO BE CERTIFIED.
8. ALL INDIRECT DRAINS TO HAVE 1" MINIMUM AIR GAP.
06/23/2006 MECHANICAL - FINAL N/A Partial Approval IVRS - Inspection :*
AS PER DISCUSSION W/MANAGER PROVIDE CLEARANCE AROUND PIZZA OVEN 13.1 VENT PIPE THRU WALL.

Completed Inspections

Permit Status: Closed
Permit Number: T06OT01488
Permit Description: C OF O: RESTAURANT
Total Completed Inspections - 3
Date Description Inspector Results Comments
06/16/2006 FIRE - FINAL FCONTRER Approved PER INSP COPY
06/16/2006 CERTIFICATE OF OCCUPANCY JBURGE Approved IVRS - Inspection :*
06/23/2006 SIGN - FINAL JYBARRA Approved IVRS - Inspection :*