Permit Details

Status:
Expired
Type:
SINGLE FAMILY OTHER
Address NEW:
6975 E LURLENE DR
Apply Date:
11/06/2006
Applicant:
PUEBLO HEATING & COOLING INC *C
Description:
INSTALL: 3 1/2 TON SPLIT SYSTEM (APA)
Contractors:
  • PUEBLO HEATING & COOLING INC *C

Outstanding Activity Conditions

Permit Number - T06ME00661
Permit Status: Expired
Permit Description: INSTALL: 3 1/2 TON SPLIT SYSTEM (APA)
Total Outstanding Activity Conditions - 1
Date Name
11/06/2006 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Outstanding Inspections

Permit Status: Expired
Permit Number: T06ME00661
Permite Description: INSTALL: 3 1/2 TON SPLIT SYSTEM (APA)
Total Outstanding Inspections - 1
Last Inspection Date Description Inspector Results Comments
01/17/2007 MECHANICAL - FINAL N/A Denied IVRS - Inspection :
See detailed listing on site.| 999*
PROVIDE A SEDIMENT TRAP ON GAS LINE AT FURNACE.
PROVIDE BUSHINGS WHERE REFER LINE CONNECTS TO COIL.
CONDENSATE CAN NO LONGER TERMINATE INTO A SEWER VENT. NO EXCEPTIONS, TERMINATE TO WITHIN 6" OF THE GROUND.