Permit: T06ME00661

Parcel: 136243520


Addresses:

6975 E LURLENE DR

Inspection Status: Denied

Inspection History: MECHANICAL - FINAL

Date Description Inspector Results Comments
01/17/2007 MECHANICAL - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
PROVIDE A SEDIMENT TRAP ON GAS LINE AT FURNACE.
PROVIDE BUSHINGS WHERE REFER LINE CONNECTS TO COIL.
CONDENSATE CAN NO LONGER TERMINATE INTO A SEWER VENT. NO EXCEPTIONS, TERMINATE TO WITHIN 6" OF THE GROUND.