Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
Expired
Type:
SINGLE FAMILY OTHER
Address:
1225 E EDISON ST
Apply Date:
08/17/2006
Applicant:
TEMP CON INC *C
Description:
REPLACE: 2 1/2 TON GAS PACK (APA)
Contractors:
  • TEMP CON INC *C

Outstanding Activity Conditions

Permit Number - T06ME00469
Permit Status: Expired
Permit Description: REPLACE: 2 1/2 TON GAS PACK (APA)
Total Outstanding Activity Conditions - 1
Date Name
08/17/2006 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Outstanding Inspections

Permit Status: Expired
Permit Number: T06ME00469
Permite Description: REPLACE: 2 1/2 TON GAS PACK (APA)
Total Outstanding Inspections - 1
Last Inspection Date Description Inspector Results Comments
09/22/2006 MECHANICAL - FINAL N/A Partial Approval IVRS - Inspection :*
DO NOT USE WHITE WIRE TO POWER THE AC UNIT.
TAPE BOTH ENDS W/BLACK TAPE.
WHITE INDICATES NEUTRAL.
IDENTIFY THE CIRCUIT BREAKER.
ADEQUATELY SECURE CONDENSATE DRAIN TO SIDE OF HOUSE. RAISE DRAIN ABOVE GRADE & TERMINATE WITH A NIPPLE & DIVERT THE WATER AWAY FROM THE HOUSE.
RECALL FOR INSPECTION.