Permit: T06ME00469
Permit Details
Apply Date:
08/17/2006
Applicant:
TEMP CON INC *C
Description:
REPLACE: 2 1/2 TON GAS PACK (APA)
Contractors:
- TEMP CON INC *C
Outstanding Activity Conditions
Permit Number - T06ME00469
Permit Status: Expired
Permit Description: REPLACE: 2 1/2 TON GAS PACK (APA)
Total Outstanding Activity Conditions - 1
Date | Name |
---|---|
08/17/2006 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Expired
Permit Number: T06ME00469
Permite Description: REPLACE: 2 1/2 TON GAS PACK (APA)
Total Outstanding Inspections - 1
Last Inspection Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
09/22/2006 | MECHANICAL - FINAL | N/A | Partial Approval | IVRS - Inspection :* DO NOT USE WHITE WIRE TO POWER THE AC UNIT. TAPE BOTH ENDS W/BLACK TAPE. WHITE INDICATES NEUTRAL. IDENTIFY THE CIRCUIT BREAKER. ADEQUATELY SECURE CONDENSATE DRAIN TO SIDE OF HOUSE. RAISE DRAIN ABOVE GRADE & TERMINATE WITH A NIPPLE & DIVERT THE WATER AWAY FROM THE HOUSE. RECALL FOR INSPECTION. |