Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T06ME00469

Parcel: 123121870


Addresses:

1225 E EDISON ST

Inspection Status: Partial Approval

Inspection History: MECHANICAL - FINAL

Date Description Inspector Results Comments
09/22/2006 MECHANICAL - FINAL Partial Approval IVRS - Inspection :*
DO NOT USE WHITE WIRE TO POWER THE AC UNIT.
TAPE BOTH ENDS W/BLACK TAPE.
WHITE INDICATES NEUTRAL.
IDENTIFY THE CIRCUIT BREAKER.
ADEQUATELY SECURE CONDENSATE DRAIN TO SIDE OF HOUSE. RAISE DRAIN ABOVE GRADE & TERMINATE WITH A NIPPLE & DIVERT THE WATER AWAY FROM THE HOUSE.
RECALL FOR INSPECTION.