Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

PRO is currently experiencing an outage. Some documents and records may not be available on PRO momentarily. We apologize for the inconvenience and are working to restore full access.

Permit Details

Status:
Closed
Type:
SINGLE FAMILY OTHER
Address NEW:
7815 E HAWTHORNE ST
Apply Date:
07/12/2006
Applicant:
RITE WAY VENTILATING CO , *C
Description:
INST: 5 TON PACKAGE UNIT (APA)
Contractors:
  • RITE WAY VENTILATING CO , *C

Outstanding Activity Conditions

Permit Number - T06ME00378
Permit Status: Closed
Permit Description: INST: 5 TON PACKAGE UNIT (APA)
Total Outstanding Activity Conditions - 1
Date Name
07/12/2006 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: Closed
Permit Number: T06ME00378
Permit Description: INST: 5 TON PACKAGE UNIT (APA)
Total Completed Inspections - 2
Date Description Inspector Results Comments
07/25/2006 MECHANICAL - FINAL JMILITEL Approved IVRS - Inspection :
See detailed listing on site.| 999*
CONDENSATE CANNOT TERMINATE INTO A SEWER VENT. PROVIDE A TRAP
TIGHTEN LOOSE ELEC. CONNECTIONS TO UNIT & DISCONNECT
IDENTIFY HEAT STRIP INSTALLED
60 AMP. BREAKER MAY NOT HANDLE THE ENTIRE LOAD.
SUPPORT ELEC. CONDUITS ON ROOF.
02/19/2010 MECHANICAL - INTERMEDIATE LHANLY Approved