Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: T06ME00172
Permit Details
Status:
Closed
Type:
SINGLE FAMILY OTHER
Address:
4525 E SAN FRANCISCO BL
Address NEW:
4525 E SAN FRANCISCO BL
Apply Date:
04/07/2006
Applicant:
RITE WAY VENTILATING CO , *C
Description:
INSTALL: 5 TON GAS PACK (APA)
Contractors:
- RITE WAY VENTILATING CO , *C
Outstanding Activity Conditions
Permit Number - T06ME00172
Permit Status: Closed
Permit Description: INSTALL: 5 TON GAS PACK (APA)
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 04/07/2006 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Closed
Permit Number: T06ME00172
Permit Description: INSTALL: 5 TON GAS PACK (APA)
Total Completed Inspections - 2
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/08/2006 | MECHANICAL - FINAL | CWILLIAM | Approved | IVRS - Inspection :* 1. CAP OLD 4" VENT OPENING W/METAL, NOT JUST TAPE. 2. PROVIDE PRESS. TEST ON NEW PIPING GAS LINE. 3. HI VOLTAGE ON ROOF., NEW CIRCUIT SWITCH INTO UNIT. TIGHTEN FLEX CONNECTORS, FITTINGS LOOSE. 4. CAP OLD FURNACE TOP W/METAL. |
| 02/18/2010 | MECHANICAL - INTERMEDIATE | LHANLY | Approved |