Inspection History Details
Inspection Status: Approved
Inspection History: MECHANICAL - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/18/2010 | MECHANICAL - FINAL | Approved | ||
| 05/08/2006 | MECHANICAL - FINAL | Partial Approval | IVRS - Inspection :* 1. CAP OLD 4" VENT OPENING W/METAL, NOT JUST TAPE. 2. PROVIDE PRESS. TEST ON NEW PIPING GAS LINE. 3. HI VOLTAGE ON ROOF., NEW CIRCUIT SWITCH INTO UNIT. TIGHTEN FLEX CONNECTORS, FITTINGS LOOSE. 4. CAP OLD FURNACE TOP W/METAL. |