Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: T06EL01864
Permit Details
Apply Date:
09/15/2006
Applicant:
ENRIQUEZ SERGIO & ALEJANDRA JT/RS
Description:
ELECTRIC UPGRADE 200 AMP
Permit Reviews
Permit Number - T06EL01864
Permit Status: Final
Permit Description: ELECTRIC UPGRADE 200 AMP
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
09/15/2006 | ELECTRICAL | 09/22/2006 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T06EL01864
Permit Status: Final
Permit Description: ELECTRIC UPGRADE 200 AMP
Total Outstanding Activity Conditions - 1
Date | Name |
---|---|
09/15/2006 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T06EL01864
Permit Description: ELECTRIC UPGRADE 200 AMP
Total Completed Inspections - 6
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
09/27/2006 | ELECTRIC - SERVICE UPGRADE | DSANTACR | Approved | IVRS - Inspection : See detailed listing on site.| 999* 1. GROUND RODS TO BE FLUSH WITH GRADE. 2. SUPPORT #4 BARE TO WALL BELOW PANEL. 3. BOND WATER & GAS PIPING 4. INSTALL ROOF JACK 5. WIRING FOR LOADS NOT ALLOWED TO BE IN SHIELDED AREA ABOVE BUSS AT TOP INSIDE PANEL. 6. TOP PENETRATION NOT APPROVED, USE SIDE OR BOTTOM OF PANEL. 7. INSTALL ADDRESS LABEL ON SERVICE. 8. USE 1/4" BOLTS TO SUPPORT RISER CONDUIT. |
01/16/2007 | TEP CLEARANCE - AM | JWEATHER | Approved | INCR CLEARED PER D. SANTACRUZ |
01/29/2007 | ELECTRIC - FINAL | RMAJUTA | Approved | IVRS - Inspection :* |
01/30/2007 | PERMIT FINALED | BFLORES | Approved | |
01/30/2007 | ELECTRIC - UNDERGROUND | RMAJUTA | Approved | |
01/30/2007 | ELECTRIC - INTERMEDIATE | RMAJUTA | Approved |