Permit: T06EL01798
Permit Details
Status:
Final
Type:
SINGLE FAMILY OTHER
Address:
859 W SANTA ROSA ST
Address NEW:
859 W SANTA ROSA ST
Apply Date:
09/06/2006
Applicant:
WOODS KENNETH
Description:
ELEC FOR SHED (T06ZV00573)
Permit Reviews
Permit Number - T06EL01798
Permit Status: Final
Permit Description: ELEC FOR SHED (T06ZV00573)
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 09/06/2006 | ELECTRICAL | 10/23/2006 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T06EL01798
Permit Status: Final
Permit Description: ELEC FOR SHED (T06ZV00573)
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 09/06/2006 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T06EL01798
Permit Description: ELEC FOR SHED (T06ZV00573)
Total Completed Inspections - 4
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/21/2006 | ELECTRIC - FINAL | DSANTACR | Approved | IVRS - Inspection : See detailed listing on site.| 999* 1. SUPPORT 3/4" EMT WITHIN 3' OF PANEL OUTSIDE AT SERVICE. 2. TYPE NM CABLE NOT APPROVED FOR UNDEGROUND USE 3. SPLICES MUST BE IN APPROVED J-BOX 4. MIN. CONDUIT DEPTH 18" BELOW GRADE FOR PVC 5. NAIL PLATES REQUIRED TO PROTECT CABLES PASSING THROUGH 1 1/2" STUDS. INSTALL BUSHINGS CORRECTLY. 6. USE ROMEX CONNECTORS FOR METAL BOX. |
| 10/01/2007 | PERMIT FINALED | BFLORES | Approved | |
| 10/01/2007 | ELECTRIC - INTERMEDIATE | DSANTACR | Approved | |
| 10/01/2007 | ELECTRIC - UNDERGROUND | DSANTACR | Approved |