Status:
Expired
Type:
SINGLE FAMILY OTHER
Address:
321 N BROWN AV
Apply Date:
07/24/2006
Applicant:
CASCADE ELECTRIC INC *C
Description:
UPGRADE: 200 AMPS (APA)
Contractors:
  • CASCADE ELECTRIC INC *C

Outstanding Activity Conditions

Permit Number - T06EL01402
Permit Status: Expired
Permit Description: UPGRADE: 200 AMPS (APA)
Total Outstanding Activity Conditions - 1
Date Name
07/24/2006 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Outstanding Inspections

Permit Status: Expired
Permit Number: T06EL01402
Permite Description: UPGRADE: 200 AMPS (APA)
Total Outstanding Inspections - 3
Last Inspection Date Description Inspector Results Comments
07/31/2006 ELECTRIC - UNDERGROUND N/A Not ready for Inspection IVRS - Inspection :*
07/31/2006 ELECTRIC - INTERMEDIATE N/A Not ready for Inspection IVRS - Inspection :*
07/31/2006 ELECTRIC - FINAL N/A Not ready for Inspection IVRS - Inspection :*
1. TIGHTEN LOOSE LOCKNUT
2. SUPPORT CONDUIT BELOW PANEL
3. PROTECT CONDUIT FROM CORROSION
4. IS NM CABLE BURIED OR FULL RACEWAY SYSTEM. IF BURIED IT MUST BE "UF"
5. FITTING TO BE LISTED FOR OUTDOOR USES
6. ARE BOXES FAN RATED
7. FILL UNUSED PORTION IN BACK OF PANEL WITH A NON-COMBUSTIBLE PRODUCT.
8. LABEL ALL BREAKERS
9. PLEASE ADD NEW CIRCUITS TO PERMIT
10. IS NEW 12-3 A MULTI CORE CIRCUIT
11. PLEASE VERIFY LOADS FOR 2 CONDUCTOR TO 1 BREAKER
12. FILL UNUSED OPENINGS IN PANEL DEAD FRONT
13. BREAKER AMPACITY TO BE SIZE PER CONDUCTORS.

Documents

File Name Document Type  
None DOCUMENTS VIEW