Permit Details

Status:
Expired
Type:
SINGLE FAMILY OTHER
Address:
1011 S ELI DR
Address NEW:
1011 S ELI DR
Apply Date:
07/10/2006
Applicant:
THE ELECTRICAL WIZARD
Description:
ELEC UPGR: 200 AMP
Contractors:
  • THE ELECTRICAL WIZARD

Permit Reviews

Permit Number - T06EL01285
Permit Status: Expired
Permit Description: ELEC UPGR: 200 AMP
Start Date Submittal Complete Date Status  
07/14/2010 ELECTRICAL 07/14/2010 ACTIVE Review Details

Outstanding Activity Conditions

Permit Number - T06EL01285
Permit Status: Expired
Permit Description: ELEC UPGR: 200 AMP
Total Outstanding Activity Conditions - 1
Date Name
07/10/2006 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Outstanding Inspections

Permit Status: Expired
Permit Number: T06EL01285
Permite Description: ELEC UPGR: 200 AMP
Total Outstanding Inspections - 1
Last Inspection Date Description Inspector Results Comments
09/04/2009 ELECTRIC - FINAL N/A Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) SEAL OPEN KNOCKOUTS IN PANEL
2) EQUIPMENT GROUND BAR CANNOT BE CONNECTED USING SHEET METAL SCREWS
3) INSTALL BREAKERS LISTED FOR USE IN SQUARE D PANEL
4) EXPOSED PVC TO BE SCHEDULE 80
5) ROMEX CABLE CANNOT BE INSTALLED IN UNDEGROUND RACEWAY THIS IS WET LOCATION
6) STRAP PVC WITHIN 3' OF CONNECTIONS TO PANEL
7) INSTALL GASKET ON LB COVER
8) WHITE CONDUCTORS USED AS PHASE CONDUCTORS TO BE RE-IDENTIFIED
9) NEED PANEL DIRECTORY
10) OPEN JUNCTION BOX FOR INSPECTION
11) VERIFY PERMIT FOR NEW A/C UNIT. PROVIDE COPY
12) INSTALL LOCK NUTS ON CONNECTORS
13) RESCHEDULE WHEN READY

Completed Inspections

Permit Status: Expired
Permit Number: T06EL01285
Permit Description: ELEC UPGR: 200 AMP
Total Completed Inspections - 3
Date Description Inspector Results Comments
07/11/2006 ELECTRIC - INTERMEDIATE RMAJUTA Approved IVRS - Inspection :*
1) CALL FOR FINAL ONCE SWITCHED OVER
07/11/2006 ELECTRIC - UNDERGROUND RMAJUTA Approved IVRS - Inspection :*
07/12/2006 TEP CLEARANCE - AM JWEATHER Approved INCR CLEARED PER R. MAJUTA