Permit: T06EL01104
Permit Details
Status:
Expired
Type:
SINGLE FAMILY OTHER
Address:
5134 E FORT LOWELL RD
Address NEW:
5134 E FORT LOWELL RD
Apply Date:
06/09/2006
Applicant:
J POWERS
Description:
ELEC UPGRADE 200AMPS
Permit Reviews
Permit Number - T06EL01104
Permit Status: Expired
Permit Description: ELEC UPGRADE 200AMPS
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 06/09/2006 | ELECTRICAL | 06/09/2006 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T06EL01104
Permit Status: Expired
Permit Description: ELEC UPGRADE 200AMPS
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 06/09/2006 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Expired
Permit Number: T06EL01104
Permite Description: ELEC UPGRADE 200AMPS
Total Outstanding Inspections - 5
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/11/2006 | ELECTRIC - CABLE DROP | N/A | Not ready for Inspection | IVRS - Inspection :* 1. POST ADDRESS OUTSIDE OF STRUCTURE 2. A PERMANENT ADDRESS LABEL IS NEEDED 3. INSTALL A GROUNDING ELECTRODE SYSTEM 4. GAS AND WATER WILL NEED TO BE BONDED 5. PVC LB TO USE A FITTING TO ATTACH TO PANEL 6. SUPPORT CONDUITS & RISER BELOW PANEL 7. MAINTAIN WORKING CLEARANCE IN FRONT OF SERVICE 3' 8. USE APPROVED ELECTRICAL SUPPORT STRAPS. 9. NO MORE THAN 360 DEGREE IN A CONDUIT RUN. A POLL BOX MAY BE NEEDED. 10. CONDUCTOR TO BE LISTED FOR DIRECT BURIAL. |
| 07/25/2006 | ELECTRIC - UNDERGROUND | N/A | Partial Approval | IVRS - Inspection :* OK 2 1/2" PVC FROM NEW SERVICE TO HOUSE OK PULL BOX |
| 10/11/2006 | ELECTRIC - INTERMEDIATE | N/A | Partial Approval | IVRS - Inspection :* |
| 10/11/2006 | ELECTRIC - SERVICE UPGRADE | N/A | Partial Approval | IVRS - Inspection :* |
| 10/11/2006 | ELECTRIC - FINAL | N/A | Partial Approval | IVRS - Inspection :* 1) IDENTIFY NEUTRAL CONDUCTOR WITH WHITE TAPE 2) SECURE GROUND TO PANEL AND WALL 3) USE A SEALING LOCK NUT ABOVE CURRENT CARRING PARTS |
Completed Inspections
Permit Status: Expired
Permit Number: T06EL01104
Permit Description: ELEC UPGRADE 200AMPS
Total Completed Inspections - 1
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/12/2006 | TEP CLEARANCE - AM | JWEATHER | Approved | INCR CLEARED PER R. HOLLANDER |