Permit Details

Status:
Expired
Type:
SINGLE FAMILY OTHER
Address NEW:
5134 E FORT LOWELL RD
Apply Date:
06/09/2006
Applicant:
J POWERS
Description:
ELEC UPGRADE 200AMPS

Permit Reviews

Permit Number - T06EL01104
Permit Status: Expired
Permit Description: ELEC UPGRADE 200AMPS
Start Date Submittal Complete Date Status  
06/09/2006 ELECTRICAL 06/09/2006 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T06EL01104
Permit Status: Expired
Permit Description: ELEC UPGRADE 200AMPS
Total Outstanding Activity Conditions - 1
Date Name
06/09/2006 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Outstanding Inspections

Permit Status: Expired
Permit Number: T06EL01104
Permite Description: ELEC UPGRADE 200AMPS
Total Outstanding Inspections - 5
Last Inspection Date Description Inspector Results Comments
07/11/2006 ELECTRIC - CABLE DROP N/A Not ready for Inspection IVRS - Inspection :*
1. POST ADDRESS OUTSIDE OF STRUCTURE
2. A PERMANENT ADDRESS LABEL IS NEEDED
3. INSTALL A GROUNDING ELECTRODE SYSTEM
4. GAS AND WATER WILL NEED TO BE BONDED
5. PVC LB TO USE A FITTING TO ATTACH TO PANEL
6. SUPPORT CONDUITS & RISER BELOW PANEL
7. MAINTAIN WORKING CLEARANCE IN FRONT OF SERVICE 3'
8. USE APPROVED ELECTRICAL SUPPORT STRAPS.
9. NO MORE THAN 360 DEGREE IN A CONDUIT RUN. A POLL BOX MAY BE NEEDED.
10. CONDUCTOR TO BE LISTED FOR DIRECT BURIAL.
07/25/2006 ELECTRIC - UNDERGROUND N/A Partial Approval IVRS - Inspection :*
OK 2 1/2" PVC FROM NEW SERVICE TO HOUSE
OK PULL BOX
10/11/2006 ELECTRIC - INTERMEDIATE N/A Partial Approval IVRS - Inspection :*
10/11/2006 ELECTRIC - SERVICE UPGRADE N/A Partial Approval IVRS - Inspection :*
10/11/2006 ELECTRIC - FINAL N/A Partial Approval IVRS - Inspection :*
1) IDENTIFY NEUTRAL CONDUCTOR WITH WHITE TAPE
2) SECURE GROUND TO PANEL AND WALL
3) USE A SEALING LOCK NUT ABOVE CURRENT CARRING PARTS

Completed Inspections

Permit Status: Expired
Permit Number: T06EL01104
Permit Description: ELEC UPGRADE 200AMPS
Total Completed Inspections - 1
Date Description Inspector Results Comments
10/12/2006 TEP CLEARANCE - AM JWEATHER Approved INCR CLEARED PER R. HOLLANDER

Documents

File Name Document Type  
T06EL01104.PDF DOCUMENTS VIEW
None CONSTRPLANS VIEW