Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Expired
Type:
SINGLE FAMILY OTHER
Address NEW:
1822 N BELL AV #01
Apply Date:
05/30/2006
Applicant:
MICHAEL VAN HALL
Description:
ELEC: RECONNECT

Outstanding Activity Conditions

Permit Number - T06EL01031
Permit Status: Expired
Permit Description: ELEC: RECONNECT
Total Outstanding Activity Conditions - 1
Date Name
05/30/2006 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Outstanding Inspections

Permit Status: Expired
Permit Number: T06EL01031
Permite Description: ELEC: RECONNECT
Total Outstanding Inspections - 2
Last Inspection Date Description Inspector Results Comments
09/21/2006 ELECTRIC - RECONNECT N/A Denied IVRS - Inspection :
See detailed listing on site.| 999*
09/21/2006 ELECTRIC - FINAL N/A Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. PLEASE VERIFY PERMITS FOR NEW WIRING TO INTERIOR
WIRE MOLD
2. M/C ABLE TO TERMINATE WITH APPROVED FITTINGS.
3. BOXES MORE THAN 1/4" FROM BOX TO SURFACE TO USE APPROVED EXTENDER RINGS 314.20
4. IF NEW WIRING IN KITCHEN PLEASE VERIFY 2 CIRCUITS SERVING COUNTER TOP.
5. WHAT IS PVC CONDUIT RUNNING THROUGH CLOSET
6. WE HAVE GROUNDED RECEPTACLES ON UNGROUNDED SYSTEM.
7. PLEASE VERIFY PERMIT FOR NEW WATER HEATER.
8. USE APPROVED FITTINGS WITH PVC BOXES.
9. PLEASE COMPLETE OLD SERVICE UPGRADE PERMIT.

Documents

File Name Document Type  
None DOCUMENTS VIEW