Permit: T06CM06345
Permit Details
Apply Date:
12/15/2006
Applicant:
PEABODY WILLIAM A & JOANN CP/RS
Description:
TI:ADA MODIFICATIONS-C/O
Contractors:
- EXTERIOR DIVERSIFIED CORP ,
Permit Reviews
Permit Number - T06CM06345
Permit Status: C of o
Permit Description: TI:ADA MODIFICATIONS-C/O
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 12/15/2006 | COMMERCIAL TI | 12/19/2006 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T06CM06345
Permit Status: C of o
Permit Description: TI:ADA MODIFICATIONS-C/O
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 12/15/2006 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: C of o
Permit Number: T06CM06345
Permit Description: TI:ADA MODIFICATIONS-C/O
Total Completed Inspections - 16
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/29/2006 | PLUMBING - ROUGH, SOIL | RRICH | Approved | IVRS - Inspection : See detailed listing on site.| 999* 1. VENT FOR STOOL SHALL BE ON DRAIN ARM OF STOOL 2. SHALL SUPPORT DWV IN WALL 3. SHALL PROVIDE FULL SIZE UPPER TERMINAL CLEANOUT FOR SINKS. 4. PROVIDE INSULATION FOR WATER PIPING EXPOSED TO FREEZING. 5. SHALL USE LONG RADIUS FITTING FOR ALL DRAINAGE AS REQUIRED. |
| 12/29/2006 | ELECTRIC - FINAL | DSANTACR | Approved | IVRS - Inspection :* 1) INSTALL COVERS AND RECALL WHEN READY |
| 12/29/2006 | PLUMBING - INTERMEDIATE | RRICH | Approved | IVRS - Inspection : See detailed listing on site.| 999* |
| 12/29/2006 | ELECTRIC - ABOVE CEILING | DSANTACR | Approved | IVRS - Inspection :* |
| 12/29/2006 | ELECTRIC - INTERMEDIATE | DSANTACR | Approved | IVRS - Inspection :* |
| 12/29/2006 | FRAMING | GDABBS | Approved | IVRS - Inspection :* |
| 01/08/2007 | MECHANICAL - FINAL | JMILITEL | Approved | IVRS - Inspection :* |
| 01/08/2007 | MECHANICAL - ABOVE CEILING | JMILITEL | Approved | IVRS - Inspection :* |
| 01/08/2007 | SHEET ROCK NAILING | GDABBS | Approved | IVRS - Inspection :* |
| 02/22/2007 | PLUMBING - FINAL | RRICH | Approved | IVRS - Inspection :* |
| 02/22/2007 | PLUMBING - PROGRESS | RRICH | Approved | IVRS - Inspection :* |
| 02/23/2007 | FIRE - FINAL | LLAKEY | Approved | |
| 03/07/2007 | BUILDING - FINAL | GDABBS | Approved | IVRS - Inspection :* |
| 03/07/2007 | CERTIFICATE OF OCCUPANCY | GDABBS | Approved | IVRS - Inspection :* |
| 03/16/2007 | PERMIT FINALED | BFLORES | Approved | |
| 04/06/2007 | SIGN - FINAL | JYBARRA | Approved |