Permit: T06CM06345

Parcel: 128062530


Addresses:

5917 E 22ND ST #02

Inspection Status: Approved

Inspection History: PLUMBING - ROUGH, SOIL

Date Description Inspector Results Comments
01/03/2007 PLUMBING - ROUGH, SOIL Approved IVRS - Inspection :*
01/02/2007 PLUMBING - ROUGH, SOIL Not ready for Inspection IVRS - Inspection :*
12/29/2006 PLUMBING - ROUGH, SOIL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. VENT FOR STOOL SHALL BE ON DRAIN ARM OF STOOL
2. SHALL SUPPORT DWV IN WALL
3. SHALL PROVIDE FULL SIZE UPPER TERMINAL CLEANOUT FOR SINKS.
4. PROVIDE INSULATION FOR WATER PIPING EXPOSED TO FREEZING.
5. SHALL USE LONG RADIUS FITTING FOR ALL DRAINAGE AS REQUIRED.