Start Date Submittal Complete Date Status  
10/24/2007 REVISION - - 1ST 10/25/2007 COMPLETED Review Details
11/20/2006 RESIDENTIAL BLDG-MODEL PLAN/ENGINE/WALK THRU 12/07/2006 COMPLETED Review Details
12/04/2006 OTHER 12/05/2006 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T06CM05990
Permit Status: Expired
Permit Description: NEW SFR TD# 16-81-27
Total Outstanding Activity Conditions - 1
Date Name
11/20/2006 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Outstanding Inspections

Permit Status: Expired
Permit Number: T06CM05990
Permite Description: NEW SFR TD# 16-81-27
Total Outstanding Inspections - 2
Last Inspection Date Description Inspector Results Comments
PERMIT FINALED N/A Not Inspected
12/13/2007 ASSURANCE N/A Partial Approval TEMPORARY C OF O. SITE APPEARS TO BE GRADED AT THIS TIME, BUT HAS SHOWN SIGNS OF HOLDING WATER IN THE PAST ADJACENT TO THE STRUCTURE. THE SITE WILL BE CHECKED BY THE ENGINEER OF RECORD AND THE REVIEWER FOR THE ENGINEERING SECTION(EBERBACH) FOR CODE COMPLIANCE PRIOR TO A FULL APPROVAL OF THIS SITE.

Completed Inspections

Permit Status: Expired
Permit Number: T06CM05990
Permit Description: NEW SFR TD# 16-81-27
Total Completed Inspections - 24
Date Description Inspector Results Comments
04/13/2007 ELECTRIC - UFER RMAJUTA Approved IVRS - Inspection :*
APPROVAL WILL BE SUBJECT TO REVISION ON PLAN
PLAN ON ELECTRICAL SHEET SHOWS A #2 COPPER TO REBAR
ON SITE A #4 COPPER IS INSTALLED.
05/29/2007 ROOF NAILING AQUIROZ Approved IVRS - Inspection :*
06/05/2007 EXT METAL CLIPS/EXT SHEATHING AQUIROZ Approved IVRS - Inspection :*
06/22/2007 PLUMBING - INTERMEDIATE RMYERS Approved IVRS - Inspection :*
CORRECTIONS MADE OK
OK TO COVER ALL AREAS
06/22/2007 PLUMBING - INTERMEDIATE RMYERS Approved IVRS - Inspection :*
1. HORIZONTAL X HORIZONTAL CHANGE OF DIRECTION TO BE A SWEEP.
2. SUPPORT PVC AT EACH CHANGE OF DIRECTION OR ELEVATION AND AT THE END OF BRANCHES, THEN NO MORE THAN FOUR FEET BETWEEN HANGERS.
3. REQUIRE 18" OF COPPER AT SERVICE AND AT WATER HEATER
4. DRAINAGE FITTINGS ON VENTS BELOW 42"
06/26/2007 STUCCO MESH AQUIROZ Approved IVRS - Inspection :*
06/29/2007 FRAMING AQUIROZ Approved IVRS - Inspection :*
07/05/2007 MECHANICAL - INTERMEDIATE JMILITEL Approved IVRS - Inspection :*
PROVIDE BACKING PRIOR TO SHEETROCK
CLEAN UP ALL LOOSE INSULATION IN SUPPLY & RETURN PLENUMS
07/19/2007 SHEET ROCK NAILING AQUIROZ Approved IVRS - Inspection :*
07/24/2007 U VALUE FOR WINDOW AQUIROZ Approved IVRS - Inspection :*
10/22/2007 ELECTRIC - CABLE DROP DSANTACR Approved IVRS - Inspection :*
10/23/2007 TEP CLEARANCE - AM JWEATHER Approved TEC CLEARED PER D. SANTACRUZ
11/27/2007 ELECTRIC - UNDERGROUND EDURAZO Approved
11/27/2007 ELECTRIC - INTERMEDIATE EDURAZO Approved
11/27/2007 ELECTRIC - OUTDOOR LIGHTING EDURAZO Approved
11/27/2007 MECHANICAL - FINAL MRAMBER Approved IVRS - Inspection :*
11/27/2007 ELECTRIC - FINAL EDURAZO Approved IVRS - Inspection :*
12/06/2007 BUILDING - FINAL EDURAZO Approved IVRS - Inspection :*
1) PROVIDE POSITIVE DRAINAGE FROM UNITS
2) OK TO OCCUPY
3) OK FOR TEMP C OF O
4) NOTE: STUCCO, INSULATION AND POST TENSION CERTS REQUIRED FOR FINAL-ALL UNITS
12/06/2007 PLUMBING - FINAL EDURAZO Approved IVRS - Inspection :*
12/06/2007 PLUMBING - SEWER HCS CONNECT EDURAZO Approved IVRS - Inspection :*
12/06/2007 PLUMBING - YARD WTR LINE/TEST EDURAZO Approved IVRS - Inspection :*
12/06/2007 BUILDING PRE-SLAB EDURAZO Approved IVRS - Inspection :*
12/06/2007 EXCAVATION/LAYOUT REBAR & ZON EDURAZO Approved IVRS - Inspection :*
06/04/2008 PLUMBING - ROUGH, SOIL EDURAZO Approved IVRS - Inspection :*

Documents

File Name Document Type  
None DOCUMENTS VIEW
None CONSTRPLANS VIEW