Start Date | Submittal | Complete Date | Status |
---|---|---|---|
10/27/2006 | RESIDENTIAL BLDG-MODEL PLAN/ENGINE/WALK THRU | 10/30/2006 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T06CM05645
Permit Status: C of o
Permit Description: SFR:TD#163142 T05-M0051
Total Outstanding Activity Conditions - 1
Date | Name |
---|---|
10/27/2006 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: C of o
Permit Number: T06CM05645
Permit Description: SFR:TD#163142 T05-M0051
Total Completed Inspections - 25
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
11/08/2006 | PLUMBING - SEWER HCS CONNECT | JRIVA | Approved | IVRS - Inspection :* |
11/08/2006 | PLUMBING - YARD WTR LINE/TEST | JRIVA | Approved | IVRS - Inspection :* |
11/08/2006 | PLUMBING - ROUGH, SOIL | JRIVA | Approved | IVRS - Inspection :* |
11/16/2006 | BUILDING PRE-SLAB | ROHAVER | Approved | IVRS - Inspection :* 1) PORCH NOT READY 2) MAIN HOUSE OK 3) REBAR VERTICAL STUB FOR UFER |
11/16/2006 | EXCAVATION/LAYOUT REBAR & ZON | ROHAVER | Approved | IVRS - Inspection :* |
11/16/2006 | ELECTRIC - UFER | ROHAVER | Approved | IVRS - Inspection :* |
12/13/2006 | ROOF NAILING | WNORTH | Approved | IVRS - Inspection :* |
12/13/2006 | EXT METAL CLIPS/EXT SHEATHING | WNORTH | Approved | IVRS - Inspection :* |
01/19/2007 | FRAMING | JRIVA | Approved | IVRS - Inspection :* OK TO INSULATE & DRYWALL WILL LEAVE PLUMBING PARTIAL TO INSURE NOTE REMAINS UNTIL FINAL SO THAT VENTS ARE NOT SHORTENED |
01/19/2007 | MECHANICAL - INTERMEDIATE | JRIVA | Approved | IVRS - Inspection :* |
01/19/2007 | ELECTRIC - INTERMEDIATE | JRIVA | Approved | IVRS - Inspection :* |
01/19/2007 | STUCCO MESH | JRIVA | Approved | IVRS - Inspection :* |
01/29/2007 | ELECTRIC - CONSTRUCTION POWER | JRIVA | Approved | |
01/29/2007 | ELECTRIC - TEMPORARY SERVICE | JRIVA | Approved | |
01/29/2007 | ELECTRIC - CABLE DROP | JRIVA | Approved | IVRS - Inspection :* |
01/30/2007 | TEP CLEARANCE - AM | JWEATHER | Approved | ECO CLEARED PER J. RIVA |
01/31/2007 | SHEET ROCK NAILING | EDURAZO | Approved | IVRS - Inspection :* |
04/06/2007 | PLUMBING - GAS PRESSURE TEST | IVR USER | Approved | IVRS - AP canceled |
04/09/2007 | PLUMBING - INTERMEDIATE | JRIVA | Approved | |
04/09/2007 | MECHANICAL - FINAL | JRIVA | Approved | IVRS - Inspection :* |
04/09/2007 | PLUMBING - FINAL | JRIVA | Approved | IVRS - Inspection :* |
04/09/2007 | ELECTRIC - FINAL | JRIVA | Approved | IVRS - Inspection :* |
04/09/2007 | BUILDING - FINAL | JRIVA | Approved | IVRS - Inspection :* |
04/09/2007 | U VALUE FOR WINDOW | JRIVA | Approved | IVRS - Inspection :* |
04/25/2007 | PERMIT FINALED | JWEATHER | Approved |