Permit: T06CM05629
Permit Details
Apply Date:
10/26/2006
Applicant:
ERIN HASTREITER
Description:
TI: RETAIL OFFICE (T06DV01173)
Architects:
- SAKELLAR, C NICHOLAS
Contractors:
- FARWEST DEVELOPMENT AND CONSTRUCTION OF THE SOUT
Permit Reviews
Permit Number - T06CM05629
Permit Status: Expired
Permit Description: TI: RETAIL OFFICE (T06DV01173)
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
02/12/2007 | POST 3RD PARTY REVIEW | 02/14/2007 | COMPLETED |
10/26/2006 | PLANS OK TO SUBMIT - 3RD PARTY | 10/31/2006 | COMPLETED |
12/04/2006 | PLANS OK TO SUBMIT - 3RD PARTY | 12/05/2006 | COMPLETED |
12/05/2006 | 3RD PARTY REVIEW-COMMERCIAL TI | 02/12/2007 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T06CM05629
Permit Status: Expired
Permit Description: TI: RETAIL OFFICE (T06DV01173)
Total Outstanding Activity Conditions - 1
Date | Name |
---|---|
10/26/2006 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Expired
Permit Number: T06CM05629
Permite Description: TI: RETAIL OFFICE (T06DV01173)
Total Outstanding Inspections - 1
Last Inspection Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
04/03/2007 | SIGN - FINAL | N/A | Partial Approval | BILLBOARD STILL EXISTS AT THIS LOCATION WITHOUT PROVIDING REQUIRED PARKING AND LOADING ZONE - DO NOT RELEASE C/O W/O APPROVAL FROM ERNIE OR CRAIG. |
Completed Inspections
Permit Status: Expired
Permit Number: T06CM05629
Permit Description: TI: RETAIL OFFICE (T06DV01173)
Total Completed Inspections - 25
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
02/15/2007 | PLUMBING - ROUGH, SOIL | BBENEDON | Approved | IVRS - Inspection :* |
02/26/2007 | FRAMING | AQUIROZ | Approved | IVRS - Inspection :* |
02/27/2007 | PLUMBING - INTERMEDIATE | RMYERS | Approved | IVRS - Inspection :* 1. GAS INSTALLED PER REDLINES - NO ENGINEERING REQ'D 2. ABS DWV THRU ROOF OK 3. COPPER OK NEED TO SEE HANGERS AT EACH CHANGE OF DIRECTION OR ELEVATION AND AT THE END OF BRANCHES - THEN EVERY SO MANY FEE PER TABLE 3-1 2003 UPC 4. OK TO COVER WALLS. |
02/27/2007 | PLUMBING - GAS PRESSURE TEST | RMYERS | Approved | IVRS - Inspection :* |
03/01/2007 | ELECTRIC - INTERMEDIATE | RMAJUTA | Approved | IVRS - Inspection :* |
03/05/2007 | SHEET ROCK NAILING | AQUIROZ | Approved | IVRS - Inspection :* |
03/13/2007 | PLUMBING - GAS PRESS TEST FNL | RMYERS | Approved | IVRS - Inspection :* CALL 03036 FOR CLOSET FLANGE INSPECTION PRIOR TO CALLING FINAL |
03/15/2007 | MECHANICAL - INTERMEDIATE | JMILITEL | Approved | IVRS - Inspection :* PLANS DRAWN & APPROVED IN ERROR. IECC SECTION 803.2.8 REQUIRES MIN. R5 DUCT INSULATION NOT R3.5 PROVIDE 1 1/2" MIN. R5 DUCT LINER OR WRAP THE OUTSIDE OF THE DUCT. INSTALL CEILING DIFFUSERS CONDENSATE DRAIN OK STRAP FLEX DUCTS EVERY 5' |
03/16/2007 | PLUMBING - ABOVE CEILING | RMYERS | Approved | IVRS - Inspection :* FLANGE OK |
03/16/2007 | BUILDING ABOVE CEILING | AQUIROZ | Approved | IVRS - Inspection :* |
03/20/2007 | ELECTRIC - ABOVE CEILING | DSANTACR | Approved | IVRS - Inspection :* |
03/22/2007 | MECHANICAL - FINAL | JMILITEL | Approved | IVRS - Inspection :* OK FOR FINAL AIR BALANCE OK |
03/22/2007 | MECHANICAL - ABOVE CEILING | JMILITEL | Approved | IVRS - Inspection :* |
03/22/2007 | ELECTRIC - FINAL | CCLEMENS | Approved | IVRS - Inspection :* |
03/26/2007 | FIRE SPKLR - FINAL | LTHOMAS | Approved | |
03/27/2007 | RIGHT OF WAY - FINAL | MOTERO | Approved | PER EMAIL |
03/27/2007 | BUILDING - FINAL | AQUIROZ | Approved | SHELL APPROVE ON 3/27/07 |
03/27/2007 | ELECTRIC - UNDERGROUND | CCLEMENS | Approved | APPROVE JOB CARD |
03/27/2007 | FIRE - FINAL | LTHOMAS | Approved | |
03/27/2007 | NPPO - FINAL | ACONNOR | Approved | |
03/27/2007 | LANDSCAPE - FINAL | ACONNOR | Approved | |
03/28/2007 | PLUMBING - FINAL | RMYERS | Approved | IVRS - Inspection :* PLUMBING FINAL OK OK FOR C OF O S.T.O.I |
03/28/2007 | PLUMBING - PRE SLAB | RMYERS | Approved | IVRS - Inspection :* |
04/02/2007 | ENGINEERING - FINAL | MRUSSO | Approved | |
05/15/2007 | ELECTRIC - TEMP POWER FOR TEST | CCLEMENS | Approved | IVRS - Inspection :* |