Permit Details

Status:
Final
Type:
SINGLE FAMILY ADDITION
Address NEW:
1026 E ALTA VISTA ST
Apply Date:
10/18/2006
Applicant:
AGBOLOSOO GRACE
Description:
ENCLOSE CARPORT TO BEDROOM & BATHRM (T05VL00824)

Permit Reviews

Permit Number - T06CM05529
Permit Status: Final
Permit Description: ENCLOSE CARPORT TO BEDROOM & BATHRM (T05VL00824)
Start Date Submittal Complete Date Status  
10/18/2006 RESIDENTIAL BLDG/ZONING/ENGINE/WWM 06/28/2007 COMPLETED Review Details

Completed Inspections

Permit Status: Final
Permit Number: T06CM05529
Permit Description: ENCLOSE CARPORT TO BEDROOM & BATHRM (T05VL00824)
Total Completed Inspections - 15
Date Description Inspector Results Comments
07/02/2007 BUILDING - FINAL CRUIZ Approved IVRS - Inspection :
See detailed listing on site.| 999*
1) GFI AT BATHROOM SINK NOT WORKING PROPERLY
2) ALL OUTLET NOT ON ARC FAULT LOOP
3) MISSING SMOKE DETECTOR
4) NO HISTORY OF PRIOR WORK BEING INSPECTED
5) NEED TO CAULK AROUND BASE OF TOILET
07/09/2007 EXT METAL CLIPS/EXT SHEATHING RCAMACHO Approved IVRS - Inspection :
See detailed listing on site.| 999*
1) SUBMIT AS BUILT FOR MASONITE SIDING. PLAN CALLS FOR ONE COAT STUCCO SYSTEM
2) PROVIDE 1" CLEARANCE FROM COMBUSTIBLES AROUND WATER HEATER B-VENT 18" ABOVE ROOF LINE AND SECURE PROPERLY
3) EXPOSE FOOTERS TO VERIFY DEPTH PER DETAIL 5/9
4) EXPOSE H2.5 CLIPS PER DETAIL 5/9
5) EXPOSE BOTTOM PLATES TO VERIFY TREATED PLATES
6) CLOSET LIGHT FIXTURE WITHIN 12" STACKABLE COMBUSTIBLES
7) MISSING SMOKE DETECTOR MASTER BEDROOM
8) PAINT ROOF VENT ABS
9) BATH GFCI DOES NOT TEST
10) CLOSET GFCI DOES NOT TEST
11) PLAN CALLS FOR 2 X 10 24" ON CENTER 2 X 6 INSTALLED
12) STOPPED INSPECTION
13) LEFT CARD
07/09/2007 ELECTRIC - UFER RCAMACHO Approved IVRS - Inspection :
See detailed listing on site.| 999*
07/09/2007 STUCCO MESH RCAMACHO Approved IVRS - Inspection :
See detailed listing on site.| 999*
07/09/2007 MECHANICAL - INTERMEDIATE RCAMACHO Approved IVRS - Inspection :
See detailed listing on site.| 999*
07/09/2007 PLUMBING - INTERMEDIATE RCAMACHO Approved IVRS - Inspection :
See detailed listing on site.| 999*
07/09/2007 ELECTRIC - INTERMEDIATE RCAMACHO Approved IVRS - Inspection :
See detailed listing on site.| 999*
07/09/2007 FRAMING RCAMACHO Approved IVRS - Inspection :
See detailed listing on site.| 999*
07/09/2007 ROOF NAILING RCAMACHO Approved IVRS - Inspection :
See detailed listing on site.| 999*
02/05/2015 PLUMBING - ROUGH, SOIL RCAMACHO Approved
02/05/2015 MECHANICAL - FINAL RCAMACHO Approved IVRS - Inspection :*
02/05/2015 PLUMBING - FINAL RCAMACHO Approved IVRS - Inspection :*
02/05/2015 ELECTRIC - FINAL RCAMACHO Approved IVRS - Inspection :*
02/05/2015 SHEET ROCK NAILING RCAMACHO Approved IVRS - Inspection :*
02/05/2015 U VALUE FOR WINDOW RCAMACHO Approved IVRS - Inspection :*