Permit: T06CM05529
Permit Details
Status:
Final
Type:
SINGLE FAMILY ADDITION
Address:
1026 E ALTA VISTA ST
Address NEW:
1026 E ALTA VISTA ST
Apply Date:
10/18/2006
Applicant:
AGBOLOSOO GRACE
Description:
ENCLOSE CARPORT TO BEDROOM & BATHRM (T05VL00824)
Permit Reviews
Permit Number - T06CM05529
Permit Status: Final
Permit Description: ENCLOSE CARPORT TO BEDROOM & BATHRM (T05VL00824)
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 10/18/2006 | RESIDENTIAL BLDG/ZONING/ENGINE/WWM | 06/28/2007 | COMPLETED |
Completed Inspections
Permit Status: Final
Permit Number: T06CM05529
Permit Description: ENCLOSE CARPORT TO BEDROOM & BATHRM (T05VL00824)
Total Completed Inspections - 15
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/02/2007 | BUILDING - FINAL | CRUIZ | Approved | IVRS - Inspection : See detailed listing on site.| 999* 1) GFI AT BATHROOM SINK NOT WORKING PROPERLY 2) ALL OUTLET NOT ON ARC FAULT LOOP 3) MISSING SMOKE DETECTOR 4) NO HISTORY OF PRIOR WORK BEING INSPECTED 5) NEED TO CAULK AROUND BASE OF TOILET |
| 07/09/2007 | EXT METAL CLIPS/EXT SHEATHING | RCAMACHO | Approved | IVRS - Inspection : See detailed listing on site.| 999* 1) SUBMIT AS BUILT FOR MASONITE SIDING. PLAN CALLS FOR ONE COAT STUCCO SYSTEM 2) PROVIDE 1" CLEARANCE FROM COMBUSTIBLES AROUND WATER HEATER B-VENT 18" ABOVE ROOF LINE AND SECURE PROPERLY 3) EXPOSE FOOTERS TO VERIFY DEPTH PER DETAIL 5/9 4) EXPOSE H2.5 CLIPS PER DETAIL 5/9 5) EXPOSE BOTTOM PLATES TO VERIFY TREATED PLATES 6) CLOSET LIGHT FIXTURE WITHIN 12" STACKABLE COMBUSTIBLES 7) MISSING SMOKE DETECTOR MASTER BEDROOM 8) PAINT ROOF VENT ABS 9) BATH GFCI DOES NOT TEST 10) CLOSET GFCI DOES NOT TEST 11) PLAN CALLS FOR 2 X 10 24" ON CENTER 2 X 6 INSTALLED 12) STOPPED INSPECTION 13) LEFT CARD |
| 07/09/2007 | ELECTRIC - UFER | RCAMACHO | Approved | IVRS - Inspection : See detailed listing on site.| 999* |
| 07/09/2007 | STUCCO MESH | RCAMACHO | Approved | IVRS - Inspection : See detailed listing on site.| 999* |
| 07/09/2007 | MECHANICAL - INTERMEDIATE | RCAMACHO | Approved | IVRS - Inspection : See detailed listing on site.| 999* |
| 07/09/2007 | PLUMBING - INTERMEDIATE | RCAMACHO | Approved | IVRS - Inspection : See detailed listing on site.| 999* |
| 07/09/2007 | ELECTRIC - INTERMEDIATE | RCAMACHO | Approved | IVRS - Inspection : See detailed listing on site.| 999* |
| 07/09/2007 | FRAMING | RCAMACHO | Approved | IVRS - Inspection : See detailed listing on site.| 999* |
| 07/09/2007 | ROOF NAILING | RCAMACHO | Approved | IVRS - Inspection : See detailed listing on site.| 999* |
| 02/05/2015 | PLUMBING - ROUGH, SOIL | RCAMACHO | Approved | |
| 02/05/2015 | MECHANICAL - FINAL | RCAMACHO | Approved | IVRS - Inspection :* |
| 02/05/2015 | PLUMBING - FINAL | RCAMACHO | Approved | IVRS - Inspection :* |
| 02/05/2015 | ELECTRIC - FINAL | RCAMACHO | Approved | IVRS - Inspection :* |
| 02/05/2015 | SHEET ROCK NAILING | RCAMACHO | Approved | IVRS - Inspection :* |
| 02/05/2015 | U VALUE FOR WINDOW | RCAMACHO | Approved | IVRS - Inspection :* |