Permit: T06CM05179
Permit Details
Status:
Expired
Type:
SINGLE FAMILY ADDITION
Address:
3101 E WAVERLY ST
Address NEW:
3101 E WAVERLY ST
Apply Date:
09/28/2006
Applicant:
THE BUILT ENVIRONMENT
Description:
REMODEL:MASTER BEDROOM:BATHROOM:ADDITION:LAUNDRY ROOM
Architects:
- HAMILTON, MATTHEW HALE
Permit Reviews
Permit Number - T06CM05179
Permit Status: Expired
Permit Description: REMODEL:MASTER BEDROOM:BATHROOM:ADDITION:LAUNDRY ROOM
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 09/28/2006 | RESIDENTIAL BLDG/ZONING-WALKTHRU | 09/28/2006 | COMPLETED |
| 09/28/2006 | RESIDENTIAL BLDG/WWM | 11/08/2006 | COMPLETED |
| 11/08/2006 | RESUBMITTAL | 11/30/2006 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T06CM05179
Permit Status: Expired
Permit Description: REMODEL:MASTER BEDROOM:BATHROOM:ADDITION:LAUNDRY ROOM
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 09/28/2006 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Expired
Permit Number: T06CM05179
Permite Description: REMODEL:MASTER BEDROOM:BATHROOM:ADDITION:LAUNDRY ROOM
Total Outstanding Inspections - 9
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/09/2007 | FRAMING | N/A | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
| 03/09/2007 | BUILDING - FINAL | N/A | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
| 03/09/2007 | ELECTRIC - INTERMEDIATE | N/A | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. DRAWINGS CALL FOR ELECTRICAL WATER HEATERS NOT GAS 2. SMOKIES NEED TO BE ON A LOOP 3. NEED RECEPTACLES IN HALLWAY 4. NEED TO GET RID OF RECEPT. AT MASTER BATH CLOSET 5. NEED MORE RECEPTACLES IN BEDROOM HABITABLE SPACE. 6. B-VENT NOT INSTALLED FOR GAS W/H 7. NEED PROTECTION PLATES ON ALL PLUMBING IN WALLS 8. WATER CLOSET/TOILET AT MASTER BATH - NEEDS MIN 15" CLEARANCE FROM SIDE TO SIDE 9. MECHANICAL AIR DUCT 10. NO GAS LINES FOR GAS FIREPLACE IN LIVING ROOM 11. NEED 2 GFI CIRCUITS ON EACH SIDE OF SINK 12. NEED TO ADD PLUMBING ROUGH SOIL TO PERMIT SIDE NEW PLUMBING IN MASTER BATH NEEDS DWV TEST |
| 03/09/2007 | ELECTRIC - FINAL | N/A | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
| 03/09/2007 | PLUMBING - INTERMEDIATE | N/A | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
| 03/09/2007 | PLUMBING - GAS PRESSURE TEST | N/A | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
| 03/09/2007 | PLUMBING - FINAL | N/A | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
| 03/09/2007 | MECHANICAL - INTERMEDIATE | N/A | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
| 03/09/2007 | MECHANICAL - FINAL | N/A | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
Completed Inspections
Permit Status: Expired
Permit Number: T06CM05179
Permit Description: REMODEL:MASTER BEDROOM:BATHROOM:ADDITION:LAUNDRY ROOM
Total Completed Inspections - 3
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/17/2007 | BUILDING PRE-SLAB | RCAMACHO | Approved | IVRS - Inspection :* |
| 03/09/2007 | ELECTRIC - PROGRESS | CRUIZ | Approved | IVRS - Inspection :* |
| 03/09/2007 | BUILDING - PROGRESS | CRUIZ | Approved | IVRS - Inspection :* |