Inspection History Details
Inspection Status: Denied
Inspection History: ELECTRIC - INTERMEDIATE
Permit Number - T06CM05179
Inspection Description - ELECTRIC - INTERMEDIATE
Inspection Status - Denied
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/09/2007 | ELECTRIC - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. DRAWINGS CALL FOR ELECTRICAL WATER HEATERS NOT GAS 2. SMOKIES NEED TO BE ON A LOOP 3. NEED RECEPTACLES IN HALLWAY 4. NEED TO GET RID OF RECEPT. AT MASTER BATH CLOSET 5. NEED MORE RECEPTACLES IN BEDROOM HABITABLE SPACE. 6. B-VENT NOT INSTALLED FOR GAS W/H 7. NEED PROTECTION PLATES ON ALL PLUMBING IN WALLS 8. WATER CLOSET/TOILET AT MASTER BATH - NEEDS MIN 15" CLEARANCE FROM SIDE TO SIDE 9. MECHANICAL AIR DUCT 10. NO GAS LINES FOR GAS FIREPLACE IN LIVING ROOM 11. NEED 2 GFI CIRCUITS ON EACH SIDE OF SINK 12. NEED TO ADD PLUMBING ROUGH SOIL TO PERMIT SIDE NEW PLUMBING IN MASTER BATH NEEDS DWV TEST |