Permit: T06CM04903
Permit Details
Status:
C of o
Type:
COMMERCIAL ALTERATION
Address:
4386 N ORACLE RD #198
Address NEW:
4386 N ORACLE RD #198
Apply Date:
09/05/2006
Applicant:
METRO PERMIT EXPRESS, INC *C
Description:
TI:RESAURANT
Contractors:
- SILVER WEST INC ,
Permit Reviews
Permit Number - T06CM04903
Permit Status: C of o
Permit Description: TI:RESAURANT
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 09/05/2006 | PLANS OK TO SUBMIT - 3RD PARTY | 09/06/2006 | COMPLETED |
| 09/06/2006 | 3RD PARTY REVIEW-COMMERCIAL TI | 11/17/2006 | COMPLETED |
| 11/17/2006 | POST 3RD PARTY REVIEW | 11/24/2006 | COMPLETED |
| 11/24/2006 | RESUBMITTAL | 12/01/2006 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T06CM04903
Permit Status: C of o
Permit Description: TI:RESAURANT
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 09/05/2006 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: C of o
Permit Number: T06CM04903
Permit Description: TI:RESAURANT
Total Completed Inspections - 38
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/15/2006 | PLUMBING - INTERMEDIATE | RMYERS | Approved | OK TO COVER UNDERGROUND EXCEPT FOR MOP SINK CONTRACTOR TO REDLINE CHANGES ON PLAN |
| 12/18/2006 | PLUMBING - ROUGH, SOIL | RMYERS | Approved | WHEN SCHEDULING INSPECTIONS, DON'T FORGET TO CALL IN BOTH PERMITS. CORRECTION AT MOP SINK - OK OK TO COVER UNDER SLAB |
| 01/08/2007 | PLUMBING - GAS PRESSURE TEST | RMYERS | Approved | IVRS - Inspection :* 1. SUPPORT ABS AT EACH CHANGE OF DIRECTION OR ELEVATION AND AT THE END OF BRANCHES. 2. NEED TO SEE REVENT FOR FLOW CONTROL. 3. GAS PRESSURE TEST OK |
| 01/08/2007 | FRAMING | AQUIROZ | Approved | IVRS - Inspection :* |
| 01/08/2007 | ELECTRIC - INTERMEDIATE | RMAJUTA | Approved | IVRS - Inspection :* |
| 01/12/2007 | SHEET ROCK NAILING | GDABBS | Approved | IVRS - Inspection :* |
| 02/07/2007 | MECHANICAL - INTERMEDIATE | JMILITEL | Approved | IVRS - Inspection :* 1) CHECKED WELDS ON GREASE DUCT 2) FOUND LEAKS IN FIELD WELDED JOINTS-RECALL FOR INSPECTION AFTER REPAIR |
| 02/09/2007 | MECHANICAL - ABOVE CEILING | JMILITEL | Approved | IVRS - Inspection :* NEED TO SEE CONDENSATE DRAIN LINES. OK TO FIRE WRAP GREASE DUCT. OK PARTIAL CEILING TILES. |
| 02/09/2007 | PLUMBING - ABOVE CEILING | RMYERS | Approved | IVRS - Inspection :* OK TO COVER ALL AREAS |
| 02/12/2007 | BUILDING ABOVE CEILING | AQUIROZ | Approved | IVRS - Inspection :* |
| 02/14/2007 | ELECTRIC - CONSTRUCTION POWER | CCLEMENS | Approved | IVRS - Inspection :* |
| 02/14/2007 | ELECTRIC - CABLE DROP | CCLEMENS | Approved | IVRS - Inspection :* |
| 02/15/2007 | TEP CLEARANCE - AM | JWEATHER | Approved | TEC CLEARED FOR PANELS A & B PER C. CLEMENS |
| 03/02/2007 | PLUMBING - GAS PRESS TEST FNL | RMYERS | Approved | IVRS - Inspection :* |
| 03/02/2007 | ELECTRIC - TEMP POWER FOR TEST | RMAJUTA | Approved | HAS ALREADY BEEN APPROVED |
| 03/09/2007 | MECHANICAL - HOOD SYSTEMS | JMILITEL | Approved | IVRS - Inspection :* |
| 03/09/2007 | MECHANICAL - HOODS | JMILITEL | Approved | IVRS - Inspection :* |
| 03/09/2007 | SIGN - FINAL | JYBARRA | Approved | IVRS - Inspection :* |
| 03/09/2007 | ENGINEERING - FINAL | MAVERY | Approved | Clean wash out rear of building. |
| 03/09/2007 | NPPO - FINAL | ACONNOR | Approved | |
| 03/09/2007 | LANDSCAPE - FINAL | ACONNOR | Approved | |
| 03/09/2007 | FIRE - KITCHEN EXH HOOD FINAL | LLAKEY | Approved | |
| 03/09/2007 | FIRE SPKLR - FINAL | LLAKEY | Approved | |
| 03/09/2007 | FIRE - FINAL | LLAKEY | Approved | |
| 03/12/2007 | RIGHT OF WAY - FINAL | MOTERO | Approved | PER EMAIL |
| 03/12/2007 | PLUMBING - FINAL | RMYERS | Approved | IVRS - Inspection :* 1. CONTRACTOR TO INSTALL C.P CLEANOUT COVERS ON SINK CLEANOUTS 2. CONTRACTOR TO INSTALL GRATES ON FLOOR SINKS 3. PLUMBING FINAL OK OK FOR C OF O S.T.O.I |
| 03/12/2007 | BUILDING - FINAL | AQUIROZ | Approved | IVRS - Inspection :* |
| 03/12/2007 | EXT METAL CLIPS/EXT SHEATHING | AQUIROZ | Approved | IVRS - Inspection :* |
| 03/12/2007 | ROOF NAILING | AQUIROZ | Approved | IVRS - Inspection :* |
| 03/12/2007 | U VALUE FOR WINDOW | AQUIROZ | Approved | IVRS - Inspection :* |
| 03/12/2007 | PLUMBING - GAS RECONNECT | RMYERS | Approved | IVRS - Inspection :* |
| 03/12/2007 | OUTDOOR LIGHTING FINAL | CCLEMENS | Approved | IVRS - Inspection :* |
| 03/12/2007 | ELECTRIC - OUTDOOR LIGHTING | CCLEMENS | Approved | IVRS - Inspection :* |
| 03/12/2007 | ELECTRIC - ABOVE CEILING | CCLEMENS | Approved | IVRS - Inspection :* |
| 03/13/2007 | ELECTRIC - FINAL | CCLEMENS | Approved | IVRS - Inspection :* |
| 03/20/2007 | HEALTH DEPT - FINAL 724-7908 | JTERRELL | Approved | |
| 03/23/2007 | MECHANICAL - FINAL | WNORTH | Approved | IVRS - Inspection :* 1) FINAL AIR BALANCE REPORT REVIEWED |
| 03/29/2007 | PERMIT FINALED | LJACKSON | Approved |