Description:
RECONNECT:GAS LINE:ELECTRIC:DUPLEX

Outstanding Activity Conditions

Permit Number - T06CM04687
Permit Status: Expired
Permit Description: RECONNECT:GAS LINE:ELECTRIC:DUPLEX
Total Outstanding Activity Conditions - 1
Date Name
08/21/2006 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Outstanding Inspections

Permit Status: Expired
Permit Number: T06CM04687
Permite Description: RECONNECT:GAS LINE:ELECTRIC:DUPLEX
Total Outstanding Inspections - 2
Last Inspection Date Description Inspector Results Comments
12/22/2006 PLUMBING - FINAL N/A Not ready for Inspection IVRS - Inspection :*
12/28/2006 PLUMBING - GAS PRESSURE TEST N/A Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) TEST GAUGE IS BROKEN, PLEASE PROVIDE WORKING TEST GAUGE IN 1/10TH POUND INCREMENTS, WITH MINIMUM TEST PRESSURE TO HAVE NO PRESSURE LOSS FOR MINIMUM TIME OF REINSPECTION
2) HAVE YOUR NEW WATER HEATER ADDED TO THIS PERMIT
3) HAVE A PERMIT AND INSPECTION FOR YOUR NEW A/C HEATING UNIT ON ROOF TO OBTAIN GAS CLEARANCE CARD
4) PROVIDE CORRECT COMBUSTION AIR FOR WATER HEATER
5) PROVIDE SEDIMENT TRAPS AT APPLIANCE GAS ENTRY TO WATER HEATER AND ROOF TOP UNIT
6) PROVIDE BONDING OF BLDG GAS SYSTEM
7) YOUR GAS PIPING SYSTEM HAS A LOAD OF 178,000 BTU DEMAND YOUR PIPE SIZE DOES NOT SEEM TO MEET THAT DEMAND
8) PROVIDE PROOF OF GRAVITY DRAIN AND 90 DEGREE TERMINATION DOWN AT BLDG EXTERIOR FOR WATER HEATER TEMPERATURE AND PRESSURE RELIEF DRAIN PIPING

Completed Inspections

Permit Status: Expired
Permit Number: T06CM04687
Permit Description: RECONNECT:GAS LINE:ELECTRIC:DUPLEX
Total Completed Inspections - 3
Date Description Inspector Results Comments
12/08/2006 TEP CLEARANCE - PM BFLORES Approved RECN PER R.MAJUTA
12/08/2006 ELECTRIC - FINAL RMAJUTA Approved IVRS - Inspection :*
12/08/2006 ELECTRIC - RECONNECT RMAJUTA Approved IVRS - Inspection :*