| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/28/2006 | PLUMBING - GAS PRESSURE TEST | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) TEST GAUGE IS BROKEN, PLEASE PROVIDE WORKING TEST GAUGE IN 1/10TH POUND INCREMENTS, WITH MINIMUM TEST PRESSURE TO HAVE NO PRESSURE LOSS FOR MINIMUM TIME OF REINSPECTION 2) HAVE YOUR NEW WATER HEATER ADDED TO THIS PERMIT 3) HAVE A PERMIT AND INSPECTION FOR YOUR NEW A/C HEATING UNIT ON ROOF TO OBTAIN GAS CLEARANCE CARD 4) PROVIDE CORRECT COMBUSTION AIR FOR WATER HEATER 5) PROVIDE SEDIMENT TRAPS AT APPLIANCE GAS ENTRY TO WATER HEATER AND ROOF TOP UNIT 6) PROVIDE BONDING OF BLDG GAS SYSTEM 7) YOUR GAS PIPING SYSTEM HAS A LOAD OF 178,000 BTU DEMAND YOUR PIPE SIZE DOES NOT SEEM TO MEET THAT DEMAND 8) PROVIDE PROOF OF GRAVITY DRAIN AND 90 DEGREE TERMINATION DOWN AT BLDG EXTERIOR FOR WATER HEATER TEMPERATURE AND PRESSURE RELIEF DRAIN PIPING |
|
| 12/22/2006 | PLUMBING - GAS PRESSURE TEST | Not ready for Inspection | IVRS - Inspection :* 1) UNABLE TO INSPECT GAS PRESSURE TEST BECAUSE OF DOG IN YARD AND NO ONE HOME |
|
| 12/15/2006 | PLUMBING - GAS PRESSURE TEST | Not ready for Inspection | IVRS - Inspection :* |