Permit: T06CM04468
Permit Details
Status:
Expired
Type:
COMMERCIAL OTHER
Address:
7485 E SYCAMORE PARK BL
Address NEW:
7485 E SYCAMORE PARK BL
Apply Date:
08/04/2006
Applicant:
A A A LANDSCAPE, JORDAN DAVIS
Description:
PRE-FAB RAMADAS,RESTROOMS, PLAYGROUND SHADE
Contractors:
- A A A LANDSCAPE
Outstanding Activity Conditions
Permit Number - T06CM04468
Permit Status: Expired
Permit Description: PRE-FAB RAMADAS,RESTROOMS, PLAYGROUND SHADE
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 08/04/2006 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Expired
Permit Number: T06CM04468
Permite Description: PRE-FAB RAMADAS,RESTROOMS, PLAYGROUND SHADE
Total Outstanding Inspections - 3
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/06/2007 | ELECTRIC - FINAL | N/A | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. CANNOT LOCATE 2ND GROUND ROD ON PEDESTAL 2. REFERRING TO ITEM #3 THE PVC CONDUITS IN J-BOX NEED TO BE EXTENDED UP TO KEEP WATER OUT AND SEALED WITH A WEATHERPROOF ITEM SUCH AS DUCT SEAL. 3. PANEL NEEDS CLEARANCE IN FRONT OF IT 4. RECEPTACLE AT RAMADA NOT PUT, OTHER IRRIGATION TRANSFORMERS NOT IN. 5. NEED SOMEONE TO MEET ON SITE - NOT INSTALLED PER PLANS. 6. DID SOMEONE CHECK ON 10' OF COPPER WATER LINE FOR UFER? |
| 03/30/2007 | OUTDOOR LIGHTING FINAL | N/A | Not ready for Inspection | IVRS - Inspection :* 1) COMPLETE ITEMS 2, 3 & 4 FROM INSPECTION ON 3/6/07 2) CONNECT GROUNDING ELECTRODE CONDUCTOR TO WATER PIPE (COPPER) WITHIN 5' OF ENTERING BLDG 3) NEED REVISION ON WORK TO BE OMITTED 4) OBSERVED 20' OF COPPER WATER PIPE IN GROUND AT RAMADA 5) 2 GROUND RODS INSTALLED FOR SERVICE PEDESTAL OK 6) INSTALL 2 GROUND RODS FOR PANEL AT RAMADA TO SUPTEMENT WATER PIPE |
| 11/21/2006 | BUILDING - FINAL | N/A | Not ready for Inspection | IVRS - Inspection :* SHADE STRUCTURES ONLY -- OK TO POUR |
Completed Inspections
Permit Status: Expired
Permit Number: T06CM04468
Permit Description: PRE-FAB RAMADAS,RESTROOMS, PLAYGROUND SHADE
Total Completed Inspections - 7
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/26/2006 | EXCAVATION/LAYOUT REBAR & ZON | GDABBS | Approved | IVRS - Inspection :* |
| 09/29/2006 | SITE - SEWER | RRICH | Approved | IVRS - Inspection :* WATER TEST THRU 2-WAY CLEANOUT TO EXISTING HCS OK 2" YARD WATER OK |
| 12/19/2006 | ELECTRIC - UNDERGROUND | RMAJUTA | Approved | IVRS - Inspection :* 1. OK TO COVER CONDUIT FROM PEDESTAL TO BLDG PROVIDE A PIPE ON TOP OF DRAIN PIPES BY RETENTION RESEVOIR TO VERIFY 18" DEPT WILL VERIFY AT FINAL. 2. ALSO, AT FINAL STRAP #4 COPPER TO PEDESTAL TO PREVENT PULLING OUT. |
| 02/06/2007 | ROOF NAILING | GDABBS | Approved | IVRS - Inspection :* 1) MUST INSTALL 18" VERTICAL GRAB BARS IN BOTH RESTROOMS AS I NOTED ON SHEET S1 TO COMPLY WITH UBC 2003 2) MUST HAVE ALL OTHER INSPECTIONS APPROVED BEFORE CALLING FOR 01090 BLDG FINAL 3) MUST REPAIR BOTH LOCK SETS ON RESTROOM DOORS BEFORE FINAL 4) RESTROOMS MUST BE WORKING FOR FINAL INSPECTION ELECTRICAL AND PLUMBING AND CLEAN AND READY TO USE |
| 02/06/2007 | FRAMING | GDABBS | Approved | IVRS - Inspection :* |
| 03/30/2007 | ELECTRIC - UFER | RJIROUDE | Approved | IVRS - Inspection :* |
| 04/02/2007 | TEP CLEARANCE - AM | JWEATHER | Approved | TMPP CLEARED PER R. JIROUDEK |