Permit: T06CM04412
Permit Details
Apply Date:
07/31/2006
Applicant:
ACEDO JULIAN M & SYLVIA E JT/RS
Description:
ADDITION:GARAGE:RE-ROOF R1 Truss review
Permit Reviews
Permit Number - T06CM04412
Permit Status: Expired
Permit Description: ADDITION:GARAGE:RE-ROOF R1 Truss review
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 02/13/2007 | REVISION - - 1ST | 11/23/2007 | COMPLETED |
| 07/31/2006 | RESIDENTIAL BLDG/ZONING-WALKTHRU | 08/22/2006 | COMPLETED |
| 11/23/2007 | REVISION - - 2ND | 05/19/2008 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T06CM04412
Permit Status: Expired
Permit Description: ADDITION:GARAGE:RE-ROOF R1 Truss review
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 07/31/2006 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Expired
Permit Number: T06CM04412
Permite Description: ADDITION:GARAGE:RE-ROOF R1 Truss review
Total Outstanding Inspections - 2
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| BUILDING - FINAL | N/A | Not Inspected | ||
| 12/01/2008 | ELECTRIC - FINAL | N/A | Partial Approval | IVRS - Inspection :* 1) LABEL CIRCUITS 2) BLANK COVER OPENING DEAD FRONT OR INSTALL SPACE BREAKER |
Completed Inspections
Permit Status: Expired
Permit Number: T06CM04412
Permit Description: ADDITION:GARAGE:RE-ROOF R1 Truss review
Total Completed Inspections - 9
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/15/2006 | EXCAVATION/LAYOUT REBAR & ZON | CTREVILL | Approved | IVRS - Inspection :* |
| 11/24/2006 | REINFORCED MASONRY PRE-GROUT | CTREVILL | Approved | IVRS - Inspection :* |
| 03/02/2007 | ROOF NAILING | CTREVILL | Approved | IVRS - Inspection :* |
| 03/02/2007 | EXT METAL CLIPS/EXT SHEATHING | CTREVILL | Approved | IVRS - Inspection :* |
| 08/08/2007 | BUILDING PRE-SLAB | DWALKER | Approved | IVRS - Inspection :* |
| 10/17/2007 | FRAMING | RCAMACHO | Approved | IVRS - Inspection : See detailed listing on site.| 999* 1) GROUND METAL BOXES 2) MAKE UP ALL SWITCHES PIG TAIL GROUNDS 3) FRONT PORCH NOT PER PLAN DETAIL R/3-SUBMIT AS BUILT OR BUILD TO PLAN 4) A/2 TRUSSES 2 POINT BEARING-MUST ALLOW 1/2" FOR DEFLECTION EXISTING WALL |
| 10/17/2007 | ELECTRIC - OUTDOOR LIGHTING | RCAMACHO | Approved | IVRS - Inspection :* |
| 10/17/2007 | ELECTRIC - INTERMEDIATE | RCAMACHO | Approved | IVRS - Inspection : See detailed listing on site.| 999* |
| 12/01/2008 | SHEET ROCK NAILING | RCAMACHO | Approved | IVRS - Inspection :* |