Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/02/2007 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 02/21/2007 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) A2 & A3 TRUSSES ARE IN OPPOSITE LOCATIONS PER TRUSS LAYOUT 2) A2 TRUSSES REQUIRE 3 POINT BEARING 3) APPROVED TO DRY IN ROOF ONLY-DO NOT LOAD ROOFING |
|
| 02/09/2007 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) ROOF NAILING NOT COMPLETE 2) TRUSS SPECS NEEDED 3) ROOF SHEATHING CAN'T RUN PARALLEL TO RAFTERS 4) COMPLETE NAILING INTO STRAPS AT PORCH BEAM 5) STRAP TOP PLATES AT PONY WALLS 6) BLOCK IN BETWEEN EXISTING RAFTERS AT TOP PLATE |