Start Date | Submittal | Complete Date | Status |
---|---|---|---|
06/30/2006 | RESIDENTIAL BLDG-MODEL PLAN/ENGINE/WALK THRU | 07/06/2006 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T06CM03857
Permit Status: C of o
Permit Description: SFR TD # 16-63-58 T06-M0055
Total Outstanding Activity Conditions - 1
Date | Name |
---|---|
06/30/2006 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: C of o
Permit Number: T06CM03857
Permit Description: SFR TD # 16-63-58 T06-M0055
Total Completed Inspections - 24
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/13/2006 | FRAMING | WNORTH | Approved | IVRS - Inspection :* 1) CANCELLED BY SUPER |
10/13/2006 | STUCCO MESH | WNORTH | Approved | IVRS - Inspection :* |
10/13/2006 | PLUMBING - GAS PRESSURE TEST | WNORTH | Approved | IVRS - Inspection :* |
10/13/2006 | MECHANICAL - INTERMEDIATE | WNORTH | Approved | IVRS - Inspection :* |
10/13/2006 | PLUMBING - INTERMEDIATE | WNORTH | Approved | IVRS - Inspection :* |
10/13/2006 | ELECTRIC - INTERMEDIATE | WNORTH | Approved | IVRS - Inspection :* |
10/31/2006 | PLUMBING - SEWER HCS CONNECT | WNORTH | Approved | IVRS - Inspection :* |
11/02/2006 | PLUMBING - ROUGH, SOIL | RFREIDIN | Approved | IVRS - Inspection :* |
11/07/2006 | ELECTRIC - UNDERGROUND | WNORTH | Approved | IVRS - Inspection :* |
11/07/2006 | ELECTRIC - UFER | WNORTH | Approved | IVRS - Inspection :* |
11/07/2006 | STEM WALL/RETAINING WALL | WNORTH | Approved | IVRS - Inspection :* |
11/07/2006 | EXCAVATION/LAYOUT REBAR & ZON | WNORTH | Approved | IVRS - Inspection :* |
11/08/2006 | BUILDING PRE-SLAB | RFREIDIN | Approved | IVRS - Inspection :* |
12/08/2006 | EXT METAL CLIPS/EXT SHEATHING | CRUIZ | Approved | IVRS - Inspection : See detailed listing on site.| 999* 1) ANCHOR BOLTS GARAGE LOOSE 2) NEED NAILS IN KING STUD THAT HAVE AN H.D. AT GARAGE 3) H.D. NORTH SIDE NEEDS RETRO MISSING SHEAR PANEL 4) MAS CLIPS AT COLUMN MISSING NAILS 5) RSP4 CLIPS MISSING AT BALLOON WALLS 6) LET IN BRACE MISSING NAILS AT S.E. CORNER 7) H.D. GARAGE WALL NEEDS BOLT TIGHTEN 8) MISSING RAT RUNS ON A02A TRUSSES 9) SHEARWALL TRANSFER AT TRUSS NEEDS ? NAILS 10) NEED MORE NAILING AT EXT. WALL BOTTOM PLATE 2ND FLOOR S.E. WALL 11) WALKED ROOF AND EVERYTHING IS OK-JUST NEED RAT RUNS |
12/08/2006 | ROOF NAILING | CRUIZ | Approved | IVRS - Inspection : See detailed listing on site.| 999* |
02/14/2007 | SHEET ROCK NAILING | CRUIZ | Approved | IVRS - Inspection :* |
03/09/2007 | ELECTRIC - TEMPORARY SERVICE | WLAHR | Approved | IVRS - Inspection :* |
03/09/2007 | ELECTRIC - CABLE DROP | WLAHR | Approved | IVRS - Inspection :* |
03/12/2007 | TEP CLEARANCE - AM | BFLORES | Approved | ECO PER W.LAHR |
04/26/2007 | MECHANICAL - FINAL | WNORTH | Approved | IVRS - Inspection :* |
04/26/2007 | PLUMBING - FINAL | WNORTH | Approved | IVRS - Inspection :* |
04/26/2007 | ELECTRIC - FINAL | WNORTH | Approved | IVRS - Inspection :* |
04/26/2007 | BUILDING - FINAL | WNORTH | Approved | IVRS - Inspection :* |
05/07/2007 | PERMIT FINALED | JWEATHER | Approved |