Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T06CM03857


Addresses:

8408 S EGYPTIAN DR


Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T06CM03857

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
04/26/2007 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
12/08/2006 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) ANCHOR BOLTS GARAGE LOOSE
2) NEED NAILS IN KING STUD THAT HAVE AN H.D. AT GARAGE
3) H.D. NORTH SIDE NEEDS RETRO MISSING SHEAR PANEL
4) MAS CLIPS AT COLUMN MISSING NAILS
5) RSP4 CLIPS MISSING AT BALLOON WALLS
6) LET IN BRACE MISSING NAILS AT S.E. CORNER
7) H.D. GARAGE WALL NEEDS BOLT TIGHTEN
8) MISSING RAT RUNS ON A02A TRUSSES
9) SHEARWALL TRANSFER AT TRUSS NEEDS ? NAILS
10) NEED MORE NAILING AT EXT. WALL BOTTOM PLATE 2ND FLOOR S.E. WALL
11) WALKED ROOF AND EVERYTHING IS OK-JUST NEED RAT RUNS