Permit: T06CM03792
Permit Details
Apply Date:
06/27/2006
Applicant:
KAREN DECOOK
Description:
ADDITION DINING RM & HOBBY RM
Permit Reviews
Permit Number - T06CM03792
Permit Status: Final
Permit Description: ADDITION DINING RM & HOBBY RM
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 03/09/2007 | REVISION - - 1ST | 03/09/2007 | COMPLETED |
| 03/30/2007 | REVISION - - 2ND | 03/30/2007 | ACTIVE |
| 06/27/2006 | RESIDENTIAL BLDG/ZONING/ENGINE/WWM | 08/21/2006 | COMPLETED |
| 08/21/2006 | RESIDENTIAL BLDG/WWM | 09/19/2006 | COMPLETED |
| 10/04/2006 | RESUBMITTAL | 11/09/2006 | COMPLETED |
| 11/14/2006 | REVISION - WALK THRU | 01/02/2007 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T06CM03792
Permit Status: Final
Permit Description: ADDITION DINING RM & HOBBY RM
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 06/27/2006 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T06CM03792
Permit Description: ADDITION DINING RM & HOBBY RM
Total Completed Inspections - 20
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/11/2006 | STEM WALL/RETAINING WALL | ROHAVER | Approved | IVRS - Inspection :* 2 #4'S REBAR MISSING #4 VERTICALS SHALL BE AT 24" O.C PER ENGINEER SPECS PROVIDE VERTICAL REBAR EXTENSIONS CK W/ENGINEER EXISTING VERTICALS ARE AT 32" O.C |
| 12/11/2006 | EXCAVATION/LAYOUT REBAR & ZON | ROHAVER | Approved | IVRS - Inspection :* |
| 02/15/2007 | ROOF NAILING | ROHAVER | Approved | IVRS - Inspection :* |
| 02/15/2007 | EXT METAL CLIPS/EXT SHEATHING | ROHAVER | Approved | IVRS - Inspection :* |
| 03/13/2007 | MECHANICAL - INTERMEDIATE | ROHAVER | Approved | IVRS - Inspection :* |
| 03/13/2007 | PLUMBING - GAS PRESSURE TEST | ROHAVER | Approved | IVRS - Inspection :* |
| 03/13/2007 | PLUMBING - INTERMEDIATE | ROHAVER | Approved | IVRS - Inspection :* |
| 03/13/2007 | FRAMING | ROHAVER | Approved | IVRS - Inspection :* |
| 03/13/2007 | U VALUE FOR WINDOW | ROHAVER | Approved | IVRS - Inspection :* |
| 04/02/2007 | SHEET ROCK NAILING | ROHAVER | Approved | IVRS - Inspection :* |
| 04/10/2007 | ELECTRIC - SERVICE UPGRADE | ROHAVER | Approved | IVRS - Inspection :* |
| 04/10/2007 | ELECTRIC - INTERMEDIATE | ROHAVER | Approved | IVRS - Inspection :* |
| 04/11/2007 | TEP CLEARANCE - AM | JWEATHER | Approved | INCR CLEARED PER R. O'HAVER |
| 07/17/2007 | BUILDING - FINAL | CRUIZ | Approved | IVRS - Inspection : See detailed listing on site.| 999* 1) REMOVE AND BLANK EXT. LIGHT SOUTHSIDE OF HOUSE 2) NEED 3' LANDING AT DOOR TO DINING ROOM TO OUTSIDE 3) NEED LANDING AT PATIO TO COURT YARD 4) NEED BUBBLE COVERS ON EXT. GFI 5) MISSING RECEPTACLE OUTLET IN DINING ROOM 6) NEED TO PAINT ABS VENT PIPE 7) IDENTIFY ALL BREAKERS IN SERVICE PANEL 8) A/C UNIT NEEDS A TRAP, PER MANUFACTURERS INSTALLATION REQUIREMENT 9) CONDENSATION LINE MUST TERMINATE 6" FROM GROUND |
| 07/17/2007 | PLUMBING - FINAL | CRUIZ | Approved | IVRS - Inspection : See detailed listing on site.| 999* |
| 07/17/2007 | ELECTRIC - FINAL | CRUIZ | Approved | IVRS - Inspection : See detailed listing on site.| 999* |
| 04/01/2008 | PLUMBING - ROUGH, SOIL | CRUIZ | Approved | |
| 04/01/2008 | ELECTRIC - OUTDOOR LIGHTING | CCRUZ | Approved | |
| 08/25/2008 | MECHANICAL - FINAL | CRUIZ | Approved | IVRS - Inspection :* |
| 08/26/2008 | PERMIT FINALED | JWEATHER | Approved |