Permit: T06CM03260
Permit Details
Apply Date:
05/31/2006
Applicant:
JACA DESIGN
Description:
GENERAL REPAIR & ELEC RECONNECT
Contractors:
- KOBY GALLAGHER CONSTRUCTION INC
Permit Reviews
Permit Number - T06CM03260
Permit Status: Expired
Permit Description: GENERAL REPAIR & ELEC RECONNECT
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
05/31/2006 | OTHER | 05/31/2006 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T06CM03260
Permit Status: Expired
Permit Description: GENERAL REPAIR & ELEC RECONNECT
Total Outstanding Activity Conditions - 1
Date | Name |
---|---|
05/31/2006 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Expired
Permit Number: T06CM03260
Permite Description: GENERAL REPAIR & ELEC RECONNECT
Total Outstanding Inspections - 4
Last Inspection Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
09/20/2006 | ELECTRIC - INTERMEDIATE | N/A | Denied | IVRS - Inspection : The wiring is not complete or does not comply with code.| 245* |
09/20/2006 | ELECTRIC - FINAL | N/A | Denied | IVRS - Inspection : The wiring is not complete or does not comply with code.| 245* 1. INSTALL ANTI-TIP DEVICE ON RANGE (SEE RANGE INSTRUCTIONS) 2. PROVIDE CONNECTOR FOR DISHWASHER CORD 3. PROVIDE CONNECTOR FOR HOOD WIRING 4. PROVIDE GFI PROTECTION FOR KITCHEN COUNTER RECEPTACLES. 5. GROUND ALL SWITCHES WITH EQUIPMENT GROUND AS REQUIRED. 6. PANEL DIRECTORY IS NOT CORRECTLY IDENTIFIED. 7. HALL SMOKE DETECTOR NOT INSTALLED PER MANUFACTURER INSTRUCTIONS. 8. PROVIDE DISCONNECTING MEANS FOR WATER HEATER. 9. BEDROOM LIGHT NOT WORKING 10. SEAL HOLE IN TOP OF SUB-PANEL ALL WORK TO BE DONE BY LICENSED ELECTRICAL CONTRACTOR. |
09/20/2006 | PLUMBING - INTERMEDIATE | N/A | Not ready for Inspection | IVRS - Inspection :* |
09/20/2006 | PLUMBING - FINAL | N/A | Not ready for Inspection | IVRS - Inspection :* - PLEASE HAVE PLAN AND PERMIT ON SITE AT TIME OF INSPECTION. - UNABLE TO TELL SCOPE OF WORK. |
Completed Inspections
Permit Status: Expired
Permit Number: T06CM03260
Permit Description: GENERAL REPAIR & ELEC RECONNECT
Total Completed Inspections - 2
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
09/20/2006 | BUILDING - FINAL | AQUIROZ | Approved | IVRS - Inspection :* |
09/20/2006 | SHEET ROCK NAILING | AQUIROZ | Approved | IVRS - Inspection :* |